Purpose: To investigate the intraocular distribution and kinetics of antibodies and nanoparticles in the experimental model.
Methods: Antibodies (whole IgG 149kDa, antigen-binding fragments 48.39 kDa) and four kinds of nondegradable nanoparticles (25, 50, 200, and 250 nm) were intravitreally injected in the right eye of New Zealand white rabbits. The average optical density and concentration were used to measure intraocular distribution and kinetics.
Results: After intravitreal injection, antibodies were distributed throughout the vitreous humor and eliminated gradually into anterior and posterior routes. Fluorescence intensity decreased 1 day after injection and was not detected 25 days after injection. The nondegradable nanoparticles migrated posteriorly to the retina 7 days after injection onward and anteriorly to the aqueous humor from 1 hour to 1 day after injection. The fluorescence intensity of the nanoparticles was relatively stable in the vitreous humor, compared to antibodies. Nanoparticles accumulated on the internal limiting membrane of the retina with no penetration into deeper retinal tissue, whereas the smaller size 25 nm nanoparticles passed across the ciliary body and moved into choroid, retina, and suprachoroidal space. A gradual decrease of nanoparticles by their sizes in the vitreous after 30 days after injection was described as the percentage ratio: 61.1% (25 nm), 69.1% (50 nm), 78.6% (200nm), and 85.3% (250 nm).
Conclusions: Our study revealed the in vivo intraocular distribution and kinetics of antibodies and nanoparticles with diverse sizes and the result might help to develop newer intraocular drugs and drug delivery systems to treat retinal diseases.
Translational Relevance: These experimental results can be valuable data for human research.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7409074 | PMC |
http://dx.doi.org/10.1167/tvst.9.6.20 | DOI Listing |
J Refract Surg
September 2025
From the Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy.
Purpose: To determine the accuracy of a new machine learning-based open-source IOL formula (PEARLS-DGS) in 100 patients who underwent uncomplicated cataract surgery and had a history of laser refractive surgery for myopic defects.
Methods: The setting for this retrospective study was HUMANITAS Research Hospital, Milan, Italy. Data from 100 patients with a history of photorefractive keratectomy or laser in situ keratomileusis were retrospectively analyzed to assess the accuracy of the formula.
Zhonghua Yan Ke Za Zhi
September 2025
Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Institute of Ophthalmology, Beijing Key Laboratory of Ophthalmology & Visual Sciences, Beijing 100730, China.
The rise of minimally invasive glaucoma surgery (MIGS) has brought new options to glaucoma treatment. However, there are significant differences between MIGS and traditional trabeculectomy in terms of surgical philosophy, applicable populations, and long-term efficacy. As a classic procedure, trabeculectomy achieves a well-documented intraocular pressure (IOP)-lowering effect but is associated with a higher risk of complications.
View Article and Find Full Text PDFVestn Oftalmol
September 2025
OOO Diagnosticheskij tsentr Zreniye, Saint Petersburg, Russia.
Objective: This study evaluated the effect of sequential therapy with different dosages of Mexidol on the stabilization of glaucomatous optic neuropathy (GON) in patients with primary open-angle glaucoma (POAG).
Material And Methods: The study included 80 patients (160 eyes) with stage II and III POAG, randomized into three groups comparable by age, gender, and distribution of glaucoma stage. All patients received sequential therapy with Mexidol (14 days parenterally followed by 90 days orally).
Asia Pac J Ophthalmol (Phila)
September 2025
Department of ophthalmology, Sarawak General Hospital, Kuching, Malaysia.
Purpose: To determine Asia Pacific cataract surgeons' attitudes toward surgical waste and toward reusing supplies and pharmaceuticals.
Design: Multinational survey of APAO members METHODS: An online survey link was distributed to APAO members through their national ophthalmology societies. Responses were deidentified and compared with those from identical survey questionnaires previously distributed to North American and European cataract surgeons.
Ophthalmol Glaucoma
September 2025
Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA. Electronic address:
Purpose: To assess the clinical outcomes of Hydrus Microstent implantation with cataract extraction for the treatment of open angle glaucoma (OAG) over a maximum of 4 years.
Design: Retrospective, single-center, single-arm, longitudinal cohort study.
Subjects: 308 patients (464 eyes) with OAG who underwent Hydrus Microstent implantation with cataract extraction between February 2019 and December 2021, followed for a median (interquartile range, IQR) of 2.