A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Intermediate to Long-Term Follow-up of Cementing Liners into Well-Fixed Acetabular Components. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The cementation of a new liner into a well-fixed acetabular component is common during revision total hip arthroplasty (THA) for many indications, but most commonly for lack of a modern, compatible, highly cross-linked polyethylene (HXLPE) liner. However, little is known about the intermediate-term to long-term durability of this strategy. The purpose of this study was to evaluate the implant survivorship, risk of complications, clinical outcomes, and radiographic results of cementing a new HXLPE liner into a well-fixed acetabular component.

Methods: We retrospectively identified 323 revision THAs in which a nonconstrained HXLPE liner was cemented into a well-fixed acetabular component. The mean age at the time of the revision THA was 63 years, and 50% of patients were female. The most common indications for revision THA were polyethylene wear and osteolysis (48%), aseptic femoral loosening (35%), and hip instability (8%). The mean follow-up was 9 years.

Results: Polyethylene liner failure occurred in 11 cases (3%). In all cases, the cemented liner dissociated from the acetabular component. At 10 years, the survivorship free from any revision was 80% (95% confidence interval [CI], 75% to 84%) and the survivorship free from any reoperation was 77% (95% CI, 72% to 82%). The most common reason for re-revision was dislocation (45% of reoperations). A dislocation occurred in 17% of cases. Hips that underwent revision for instability were significantly more likely to dislocate compared with hips that underwent revision for liner wear (hazard ratio [HR], 2.3 [95% CI, 1.2 to 4.5]; p = 0.02). Elevated rim or face-changing liners were significantly more likely to dissociate than flat liners (HR, 9.0 [95% CI, 1.2 to 70.6]; p = 0.04).

Conclusions: Cementation of a nonconstrained HXLPE liner into a well-fixed acetabular component during revision THA provided durable fixation with only a small number of failures at the cement interface (3%). Instability after this procedure remains a concern, but this is multifactorial in nature. These data support the continued use of this technique, when necessary, during revision THA.

Level Of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.19.01441DOI Listing

Publication Analysis

Top Keywords

well-fixed acetabular
20
acetabular component
16
hxlpe liner
16
liner well-fixed
12
revision tha
12
revision
9
liner
8
nonconstrained hxlpe
8
survivorship free
8
hips underwent
8

Similar Publications