A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Intra-individual reproducibility of galectin-1, haptoglobin, and nesfatin-1 as promising new biomarkers of immunometabolism. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Galectin-1, haptoglobin, and nesfatin-1 have recently emerged as promising biomarkers implicated in immunometabolism. However, whether single blood measurements of these analytes could be suitable for large-scale human studies has not yet been evaluated.

Methods: The concentrations of galectin-1, haptoglobin, and nesfatin-1 were measured over a 4-month period in 207 healthy adults with median age of 56.7 years. Biomarker intra-individual reproducibility was assessed based on calculation of intraclass correlation coefficients (ICCs) and examining Bland-Altman plots.

Results: The overall ICCs were excellent for nesfatin-1 (ICC: 0.89 (95% CI: 0.86, 0.92), and good for galectin-1 and haptoglobin (ICCs: 0.70 (95% CI: 0.61, 0.77) and 0.67 (95% CI: 0.57, 0.74), respectively). Bland-Altman plots supported a high level of agreement between repeated biomarker measurements.

Conclusions: Assay measurements of galectin-1, haptoglobin, and nesfatin-1 showed good to excellent within-subject reproducibility over a 4-month period, indicating that they may serve as feasible and reliable biomarkers for assessing metabolic inflammation in population research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7424788PMC
http://dx.doi.org/10.1016/j.metop.2020.100034DOI Listing

Publication Analysis

Top Keywords

galectin-1 haptoglobin
20
haptoglobin nesfatin-1
16
intra-individual reproducibility
8
promising biomarkers
8
4-month period
8
galectin-1
5
haptoglobin
5
nesfatin-1
5
reproducibility galectin-1
4
nesfatin-1 promising
4

Similar Publications