A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: Network is unreachable

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The feasibility and effectiveness of a streamlined single-catheter approach for radiofrequency atrial fibrillation ablation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Catheter ablation for atrial fibrillation (AF) traditionally requires the use of circular mapping catheter (CMC) for pulmonary vein isolation (PVI). This study aimed to assess the feasibility and effectiveness of a CMC-free approach for AF ablation performed by a contiguous optimized (CLOSE) ablation protocol.

Methods: A CLOSE-guided and CMC-free PVI protocol with a single transseptal puncture was attempted in 67 patients with AF. Left atrial (LA) CARTO voltage mapping was performed with the ablation catheter pre- and postablation to demonstrate entry block into the pulmonary veins, and pacing maneuvers were used to confirm exit block.

Results: The CMC-free approach was successful in achieving PVI in 66 (98.5%) cases, with procedure time of 148 ± 32 minutes, ablation time of 27.5 ± 5.7 minutes, and fluoroscopy time of 7.8 ± 1.0 minutes. First-pass PVI was seen in 58(86.5%) patients, and pacing maneuvers successfully identified the residual gap in eight of the other nine cases. No complication was observed. At 12 months follow-up, 60 (89.6%) patients remained free from AF. The CMC-free approach resulted in a cost saving of £47,190.

Conclusion: A CMC-free CLOSE-guided PVI approach is feasible, safe, and cost-saving, and is associated with excellent clinical outcomes at 1 year.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7411237PMC
http://dx.doi.org/10.1002/joa3.12390DOI Listing

Publication Analysis

Top Keywords

cmc-free approach
12
feasibility effectiveness
8
atrial fibrillation
8
pacing maneuvers
8
ablation
6
approach
5
pvi
5
cmc-free
5
effectiveness streamlined
4
streamlined single-catheter
4

Similar Publications