A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Reducing Inpatient Hypoglycemia in the General Wards Using Real-time Continuous Glucose Monitoring: The Glucose Telemetry System, a Randomized Clinical Trial. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Use of real-time continuous glucose monitoring (RT-CGM) systems in the inpatient setting is considered investigational. The objective of this study was to evaluate whether RT-CGM, using the glucose telemetry system (GTS), can prevent hypoglycemia in the general wards.

Research Design And Methods: In a randomized clinical trial, insulin-treated patients with type 2 diabetes at high risk for hypoglycemia were recruited. Participants were randomized to RT-CGM/GTS or point-of-care (POC) blood glucose testing. The primary outcome was difference in inpatient hypoglycemia.

Results: Seventy-two participants were included in this interim analysis, 36 in the RT-CGM/GTS group and 36 in the POC group. The RT-CGM/GTS group experienced fewer hypoglycemic events (<70 mg/dL) per patient (0.67 [95% CI 0.34-1.30] vs. 1.69 [1.11-2.58], = 0.024), fewer clinically significant hypoglycemic events (<54 mg/dL) per patient (0.08 [0.03-0.26] vs. 0.75 [0.51-1.09], = 0.003), and a lower percentage of time spent below range <70 mg/dL (0.40% [0.18-0.92%] vs. 1.88% [1.26-2.81%], = 0.002) and <54 mg/dL (0.05% [0.01-0.43%] vs. 0.82% [0.47-1.43%], = 0.017) compared with the POC group. No differences in nocturnal hypoglycemia, time in range 70-180 mg/dL, and time above range >180-250 mg/dL and >250 mg/dL were found between the groups. The RT-CGM/GTS group had no prolonged hypoglycemia compared with 0.20 episodes <54 mg/dL and 0.40 episodes <70 mg/dL per patient in the POC group.

Conclusions: RT-CGM/GTS can decrease hypoglycemia among hospitalized high-risk insulin-treated patients with type 2 diabetes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7576426PMC
http://dx.doi.org/10.2337/dc20-0840DOI Listing

Publication Analysis

Top Keywords

hypoglycemia general
8
real-time continuous
8
continuous glucose
8
glucose monitoring
8
glucose telemetry
8
telemetry system
8
randomized clinical
8
clinical trial
8
rt-cgm/gts group
8
glucose
5

Similar Publications