A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Design, Characterization, and Analysis of PZT Micromachined Piezoelectric Ultrasonic Transducers With Good Coupling to Solids. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This article presents the piezoelectric micromachined ultrasonic transducer (PMUT) and its arrays that were based on a sputtered PZT/Si diaphragm structure and prototyped from an SOI substrate. Due to the high piezoelectric coefficient of PZT, polarization tuning pretreatment, and membrane thickness optimization, the PMUT shows high transmitting sensitivity in air and good coupling capability to liquid and solid. The PMUT transmitter exhibited a high sensitivity of 809, 190, and 135 nm/V at a resonant frequency of 0.450, 0.887, and 1.689 MHz, respectively, in air. The 5 ×5 array of 0.5-MHz PMUTs' acoustic output in water was measured as 42.4 Pa at a distance of 3 cm with a 10.0- [Formula: see text] input. Thickness-measuring ability in solids was evaluated with an 8 ×8 array of 1-MHz PMUTs as transmitter providing 8.0- [Formula: see text] input and another single PMUT of identical frequency response as receiver showing 0.2 [Formula: see text] (after 20 times magnification) output when the acoustic wave was transmitted through a 5-cm-thick graphite plate. Meanwhile, the time response of the receiver through different thicknesses of graphite plates is in reasonable agreement with predication from the analytical calculation. This high-performance PMUT with good coupling to solids will be utilized in various applications for solid-state sensing and detecting or as an alternative to the bulk piezoelectric ceramic transducers in the near future.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2020.2995424DOI Listing