Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Vitamin K antagonists are the only approved oral anticoagulants for long-term prophylaxis against valve thrombosis and thromboembolism in patients with a mechanical heart valve. Despite the proven efficacy and safety of anticoagulation with the oral direct factor Xa inhibitor apixaban compared with warfarin in high-risk populations including subjects with atrial fibrillation or with venous thromboembolism, it remains unknown whether patients with a mechanical heart valve can be safely managed with apixaban. The On-X Aortic Heart Valve and On-X Ascending Aortic Prosthesis with the Vascutek Gelweave Valsalva Graft may have lower rates of valve thrombosis and thromboembolism than conventional bileaflet and tilting disc valves due its unique pyrolytic carbon composition and flared inlet design. DESIGN: PROACT Xa is a randomized, multicenter, open-label, active-controlled trial comparing apixaban with warfarin in patients with an On-X Aortic Heart Valve or On-X Ascending Aortic Prosthesis with the Vascutek Gelweave Valsalva Graft. The study will randomize approximately 1,000 patients from approximately 60 sites in North America who underwent aortic valve replacement at least 3 months prior. Patients will be randomized 1:1 to receiving apixaban 5 mg twice daily or warfarin with a target international normalized ratio of 2.0-3.0. The last randomized participant will be followed for at least 2 years. The primary efficacy outcome is the composite of valve thrombosis and valve-related thromboembolism, and the primary safety outcome is major bleeding. Assuming the primary outcome occurs in warfarin-anticoagulated patients at a rate of 1.75%/patient-year, the study has more than 90% power to assess noninferiority of apixaban treatment with an absolute noninferiority margin of 1.75%/patient-year. A second co-primary analysis is to compare the hazard rate for the apixaban arm to twice the objective performance criterion for thromboembolism and valve thrombosis, that is, 3.4%/patient-year. SUMMARY: PROACT Xa will determine whether patients with an On-X Aortic Heart Valve can be anticoagulated with apixaban as an alternative to warfarin.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7484170PMC
http://dx.doi.org/10.1016/j.ahj.2020.06.014DOI Listing

Publication Analysis

Top Keywords

heart valve
24
on-x aortic
16
aortic heart
16
valve thrombosis
16
patients mechanical
12
valve
11
design proact
8
proact randomized
8
randomized multicenter
8
multicenter open-label
8

Similar Publications

Background: Evidence informing clinical guidelines assumes that all transcatheter aortic valve implantation (TAVI) devices have similar effectiveness, in other words, displaying a class effect across TAVI valves. We aimed to assess the comparative effectiveness of different TAVI platforms relative to other TAVI counterparts or surgical aortic valve replacement (SAVR).

Methods: MEDLINE/Embase/CENTRAL were searched from inception until April 2025, for randomized controlled trials comparing outcomes with different commercially available TAVI devices relative to other TAVI counterparts or SAVR.

View Article and Find Full Text PDF

Robotic mitral repair is often associated with longer ischaemic and cardiopulmonary bypass times, particularly early in the learning curve. We demonstrate a semi-continuous, three-suture technique for robotic annuloplasty that retains the mechanical principles of traditional interrupted sutures while leveraging the advantages of robotic precision and exposure. The use of pre-knotted sutures minimizes intra-cardiac knot tying, further enhancing procedural efficiency.

View Article and Find Full Text PDF

A Novel Technique to Extract Implanted Leads Using Simple Stylets and Reused Rotational Sheaths in Patients with a Cardiac Implantable Electronic Device.

Turk Kardiyol Dern Ars

September 2025

Division of Arrhythmia and Electrophysiology, Department of Cardiology, University of Health Sciences, Yuksek Ihtisas Cardiovascular Building, Ankara City Hospital, Ankara, Türkiye.

Objective: Transvenous lead extraction (TLE) is used in various clinical scenarios, such as device-related infections. Mechanically powered sheaths are one of the most commonly used tools for TLE procedures. We evaluated the procedural and clinical outcomes of a novel extraction technique for chronically implanted leads in the treatment of device-related infections.

View Article and Find Full Text PDF

Standardising cardiac CT-based personalised surgical planning and execution in congenital aortic valvar disease.

Cardiol Young

September 2025

Congenital Valve Procedural Planning Program, Division of Pediatric Cardiac Surgery, Cleveland Clinic Children's, and Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA.

Background: Congenital aortic valvar disease represents a heterogeneous population with suboptimal surgical repair or replacement outcomes. We assess our approach and short-term outcomes in this population using cardiac CT evaluation for personalised surgical planning and execution.

Methods: We assessed patients who underwent aortic valvar surgery from February 2022 to August 2024.

View Article and Find Full Text PDF

Background: Asymmetric underexpansion of transcatheter heart valves (THVs), as observed on fluoroscopy, may influence prosthesis function or long-term durability of transcatheter aortic valve implantation (TAVI).

Aims: This study aimed to evaluate the effect of stent frame asymmetry on hemodynamic performance and clinical outcomes in ACURATE neo and neo2 THVs.

Methods: In a retrospective registry, the TAVI asymmetry index was defined as the ratio of the THV stent frame diameter.

View Article and Find Full Text PDF