Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To evaluate the safety and efficacy of the novel SELUTION sustained-limus-release (SLR) drug-eluting balloon (DEB) in the treatment of femoropopliteal lesions. Between October 2016 and May 2017, 50 subjects (mean age 69.6±10.4 years; 29 men) with symptomatic moderate to severe lower limb ischemia (Rutherford categories 2 or 3) were enrolled at 4 German centers for the SELUTION SLR first-in-human trial ( NCT02941224). The SELUTION SLR utilizes micro-reservoirs (biodegradable polymer spheres containing sirolimus) embedded within an amphipathic membrane coated onto an angioplasty balloon. The biodegradable reservoirs are transferred to the target vessel lumen during brief balloon inflation. The primary trial objective was comparison of angiographic late lumen loss at 6 months against an objective performance criterion (OPC) value of 1.04 mm for uncoated balloon angioplasty. Secondary endpoints included device, procedural, and clinical success; clinical and imaging assessments of primary patency and restenosis; functional assessments including Rutherford category and ankle-brachial index (ABI); and major adverse events [composite of cardiovascular mortality, index limb amputation, target limb thrombosis, and clinically-driven target lesion revascularization (CD-TLR)]. At 6 months, median angiographic late lumen loss following SELUTION SLR treatment was 0.19 mm (range -1.16 to 3.07). Mean angiographic late lumen loss (n=34) was 0.29±0.84 mm (95% CI -0.01 to 0.58), significantly lower than the 1.04-mm OPC value (p<0.001). The rate of primary patency by duplex ultrasound was 88.4%, and freedom from angiographic binary restenosis was 91.2%. Through 6 months, there was significant improvement over baseline in Rutherford categories (p<0.001) and in ABI measurements (p<0.001). A single case (2%) of CD-TLR occurred at 5 months. There were no other major adverse events. Through 6 months, the SELUTION SLR DEB appears to inhibit restenosis effectively and safely, improving outcomes in subjects with symptomatic femoropopliteal disease.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1526602820941811DOI Listing

Publication Analysis

Top Keywords

selution slr
12
angiographic late
12
late lumen
12
lumen loss
12
selution sustained-limus-release
8
drug-eluting balloon
8
femoropopliteal lesions
8
selution
5
balloon
5
six-month outcomes
4

Similar Publications

Background: The treatment of ST-elevation myocardial infarction (STEMI) has significantly advanced with the introduction of primary percutaneous coronary intervention (PCI). While primary PCI with drug-eluting stents is widely accepted as the standard treatment, concerns regarding in-stent restenosis and stent thrombosis persist. Drug-coated balloons (DCBs) offer a promising alternative, delivering antiproliferative drugs directly to the vessel walls without leaving any metal behind.

View Article and Find Full Text PDF

Background: Repeat drug-eluting stenting is superior to balloon angioplasty for prevention of recurrent in-stent restenosis (ISR), but carries a potential disadvantage of multiple layers of stent. The safety and effectiveness of a sirolimus drug-eluting balloon as an alternative has not been assessed.

Study Design And Methods: The SELUTION4ISR trial is a prospective, multicenter, single-blinded, randomized, controlled trial.

View Article and Find Full Text PDF

Real-World 12-Month Outcomes with Sirolimus-Coated Balloon Angioplasty for Complex Femoropopliteal Disease.

J Clin Med

January 2025

Department of Vascular and Endovascular Surgery, Rhein Main Vascular Center, Asklepios Clinics Langen, Paulinen Wiesbaden, 63225 Langen, Germany.

: Sirolimus-coated balloons (SCBs) have emerged as a promising alternative to paclitaxel-coated devices for the treatment of femoropopliteal lesions. However, real-world data on SCB performance in also complex peripheral arterial disease remains unknown. We sought to evaluate the safety and 12-month clinical outcomes of the Selution SLR™ balloon angioplasty in a challenging real-world patient cohort.

View Article and Find Full Text PDF

Purpose: The aim of PRISTINE was to evaluate the 6 and 12 months safety and efficacy of the Selution Sustained Limus Release (SLR)™ sirolimus-coated balloon for treatment of complex lower limb occlusive lesions (TASC II C & D) in patients with chronic limb threatening ischemia (CLTI) from Singapore.

Methods: PRISTINE was a prospective, non-randomized, single arm, observational, multi-investigator, single-center clinical study. Complication-free survival at 30 days was the safety clinical endpoint.

View Article and Find Full Text PDF

Background: Sirolimus-coated balloons (SCB) for the treatment of femoropopliteal (FP) lesions have not been systematically studied, but initial outcomes from early studies are promising.

Objectives: The authors sought to evaluate the safety and efficacy of the SELUTION SLR SCB, composed of proprietary microreservoir technology combining sirolimus and biodegradable polymer, when used to treat mild-to-moderate FP disease in a Japanese population.

Methods: This multicenter, prospective, single-arm study (SELUTION SFA JAPAN) enrolled 134 patients with FP disease.