Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: To report on the development of AOSpine CROST (Clinician Reported Outcome Spine Trauma) and results of an initial reliability study.
Methods: The AOSpine CROST was developed using an iterative approach of multiple cycles of development, review, and revision including an expert clinician panel. Subsequently, a reliability study was performed among an expert panel who were provided with 20 spine trauma cases, administered twice with 4-week interval. The results of the developmental process were analyzed using descriptive statistics, the reliability per parameter using Kappa statistics, inter-rater rater agreement using intraclass correlation coefficient (ICC), and internal consistency using Cronbach's α.
Results: The AOSpine CROST was developed and consisted of 10 parameters, 2 of which are only applicable for surgically treated patents ('Wound healing' and 'Implants'). A dichotomous scoring system ('yes' or 'no' response) was incorporated to express expected problems for the short term and long term. In the reliability study, 16 (84.2%) participated in the first round and 14 (73.7%) in the second. Intra-rater reliability was fair to good for both time points (κ = 0.40-0.80 and κ = 0.31-0.67). Results of inter-rater reliability were lower (κ = 0.18-0.60 and κ = 0.16-0.46). Inter-rater agreement for total scores showed moderate results (ICC = 0.52-0.60), and the internal consistency was acceptable (α = 0.76-0.82).
Conclusions: The AOSpine CROST, an outcome tool for the surgeons, was developed using an iterative process. An initial reliability analysis showed fair to moderate results and acceptable internal consistency. Further clinical validation studies will be performed to further validate the tool.