Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The surface of human silicone breast implants is covalently grafted at a high density with a 2-methacryloyloxyethyl phosphorylcholine (MPC)-based polymer. Addition of cross-linkers is essential for enhancing the density and mechanical durability of the MPC graft. The MPC graft strongly inhibits not only adsorption but also the conformational deformation of fibrinogen, resulting in the exposure of a buried amino acid sequence, γ377-395, which is recognized by inflammatory cells. Furthermore, the numbers of adhered macrophages and the amounts of released cytokines (MIP-1α, MIP-1β, IL-8, TNFα, IL-1α, IL-1β, and IL-10) are dramatically decreased when the MPC network is introduced at a high density on the silicone surface (cross-linked PMPC-silicone). We insert the MPC-grafted human silicone breast implants into Yorkshire pigs to analyze the effect of the MPC graft on the capsular formation around the implants. After 6 month implantation, marked reductions of inflammatory cell recruitment, inflammatory-related proteins (TGF-β and myeloperoxidase), a myoblast marker (α-smooth muscle actin), vascularity-related factors (blood vessels and VEGF), and, most importantly, capsular thickness are observed on the cross-linked PMPC-silicone. We propose a mechanism of the MPC grafting effect on fibrous capsular formation around silicone implants on the basis of the and results.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.0c07629DOI Listing

Publication Analysis

Top Keywords

silicone breast
12
breast implants
12
mpc graft
12
covalently grafted
8
2-methacryloyloxyethyl phosphorylcholine
8
formation silicone
8
human silicone
8
high density
8
cross-linked pmpc-silicone
8
capsular formation
8

Similar Publications

Development of breast-mimicking phantoms for use in optical coherence elastography.

J Biomed Opt

December 2025

The University of Western Australia, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, BRITElab, Perth, Western Australia, Australia.

Significance: Optical coherence elastography (OCE) is an emerging technique for mapping tissue mechanical properties into an image, known as an elastogram, with microscale resolution. Although system characterization phantoms are widely used in OCE development, there is a critical need for tissue-mimicking phantoms that can more accurately replicate the complex structural and mechanical properties of tissues, particularly for validating clinical applications, such as in breast cancer.

Aim: We aim to investigate the effects of tissue-like structures on elastogram formation in a controlled environment by developing and characterizing two types of breast tissue-mimicking phantoms, replicating invasive ductal carcinoma (IDC) morphology and the other mimicking breast ductal networks.

View Article and Find Full Text PDF

The Efficacy of Doxorubicin in Capsule Contracture Associated with Silicone Implants.

Aesthetic Plast Surg

September 2025

Department of Plastic Reconstructive and Aesthetic Surgery, School of Medicine, Cukurova University, Balcali Hospital, Adana, Turkey.

Background: Capsule contracture (CC) is a significant complication of silicone implant use. It leads to patient dissatisfaction and reoperations following aesthetic breast augmentation and reconstruction. Prolonged inflammation and abnormal fibrosis are known to play roles in the development of CC.

View Article and Find Full Text PDF

A 56-year-old woman developed a persistent fever following right transurethral ureterolithotripsy. Approximately two weeks prior to the onset of fever, she had sustained chest trauma and had a 20-year history of bilateral silicone breast implants. Physical examination, including breast assessment, was unremarkable.

View Article and Find Full Text PDF

Cosmetic liquid silicone injections can result in silicone-induced inflammation, chronic mastitis, migration to distant locations and lymphadenitis which can result in false positive nodal and distant metastases. This study demonstrates a patient with multifocal FDG-avid right breast malignancy with FDG-avid bilateral axillary, mediastinal and abdominopelvic lymph nodes. She also had extensive FDG-avid foci in the bilateral breasts and subcutaneous gluteal regions secondary to cosmetic silicone administration.

View Article and Find Full Text PDF

Cells and Shells: Investigating How Breast Implant Shells Negatively Impact Cell Viability In Vitro.

J Biomed Mater Res B Appl Biomater

September 2025

Laboratory of Bioregenerative Medicine and Surgery, Department of Surgery, Weill Cornell Medicine, New York, New York, USA.

The pathophysiology of breast implant-related adverse outcomes, such as capsular contracture and breast implant-associated anaplastic large cell lymphoma, remains poorly understood. Herein, we explore the direct and indirect effects of smooth and textured implant shells on the viability of cell lines found within the peri-breast implant environment in vitro. The outer silicone shells of Allergan and Mentor breast implants were de-gelled and cut to exactly line the walls of 96-well cell culture plates.

View Article and Find Full Text PDF