A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Improved conductivity of flower-like MnWO on defect engineered graphitic carbon nitride as an efficient electrocatalyst for ultrasensitive sensing of chloramphenicol. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Environmental hazards caused by chloramphenicol has attained special attention. Fast, accurate and reliable detection of chloramphenicol in foodstuffs and water samples is of utmost importance. Herein, we developed a g-CN/MnWO composite for the selective and sensitive detection of chloramphenicol. Successful fabrication of g-CN/MnWO composite was verified by using scanning electron microscopy (SEM), transmission electron microscopy (TEM), Raman spectroscopy, Fourier transform infrared spectroscopy (FT-IR), x-ray diffraction (XRD) and x-ray photo electron spectroscopy (XPS) techniques. Electrochemical characteristics were evaluated by using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The g-CN/MnWO modified glassy carbon electrode has shown the highest electrocatalytic activity towards chloramphenicol with a decreased reduction potential of -0.547 V and increased cathodic peak current. The developed sensor has shown excellent performance for the detection of chloramphenicol with a sensitivity of 0.9986 μA nM cm and LOD of 1.03 nM in a broad linear range of 4.0-71 nM. In addition, the fabricated sensor has achieved anti-interference ability, good stability, excellent repeatability and remarkable reproducibility for the detection of chloramphenicol. The fabricated sensor applied for the determination of chloramphenicol in milk, human blood serum and sewage samples, in which significant and satisfactory results were achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2020.122868DOI Listing

Publication Analysis

Top Keywords

detection chloramphenicol
16
chloramphenicol
8
g-cn/mnwo composite
8
electron microscopy
8
fabricated sensor
8
improved conductivity
4
conductivity flower-like
4
flower-like mnwo
4
mnwo defect
4
defect engineered
4

Similar Publications