Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Polycystic liver disease (PCLD) is a rare condition that most often occurs in patients with polycystic kidney disease and less commonly as an isolated liver disease. Complications include cyst rupture, infection, hemorrhage, and compression of surrounding organs by large cysts. We present the case of a patient with a history of PCLD who presented to our hospital with palpitations and was found to have atrial fibrillation. Imaging and echocardiograph revealed a dominant large cyst compressing the right atrium. Other etiologies including thyroid disease, ischemic heart disease, and electrolytes abnormalities were excluded. The patient refused surgical intervention and was conservatively treated with rate control and anticoagulation. To the best of our knowledge, this is the first case of new-onset atrial fibrillation secondary to right atrial compression by a liver cyst. Compression of cardiac chambers resulting in new-onset arrhythmia should be considered when evaluating patients with PCLD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7273405PMC
http://dx.doi.org/10.7759/cureus.7976DOI Listing

Publication Analysis

Top Keywords

atrial fibrillation
12
polycystic liver
8
liver disease
8
disease
5
liver cardiac
4
compression
4
cardiac compression
4
compression leading
4
atrial
4
leading atrial
4

Similar Publications

Patients with atrial fibrillation, venous thrombosis, and mechanical heart valve (MHV) regularly undergo procedures on a daily basis, for which they require bridging anticoagulation, but this poses significant challenges. Bridging anticoagulation involves temporary interruption of long-term anticoagulation therapy for procedures and continued overlap with short-acting anticoagulants during perioperative period. Heparin-based agents are often used for overlapping in perioperative period to reduce the risk of thromboembolism, but the evidence for benefit particularly in patients with MHV remains limited.

View Article and Find Full Text PDF

We report the first use of the EnSite X system for intraoperative electrophysiological mapping during a robotic hybrid ablation (ROK-AF procedure) for long-standing persistent atrial fibrillation. Epicardial ablation targets were identified, and post-ablation electrical silencing was validated. Unlike conventional systems, its orientation-independent omnipolar technology provides directional activation vectors, high-resolution electrograms, and peak frequency analysis, thereby enhancing substrate characterisation.

View Article and Find Full Text PDF

Background: Catheter ablation is beneficial in patients with symptomatic persistent atrial fibrillation (PerAF), and pulsed field ablation (PFA) is a promising energy source to safely and durably create ablation lesions. However, catheter-specific "PFA waveforms and designs" result in effectiveness and safety profiles that are not transferable to other PFA technologies. A head-to-head comparison between the dual-energy, wide-footprint lattice-tip (Sphere-9, Medtronic) and pentaspline PFA catheter (Farawave, Boston Scientific) is not yet available.

View Article and Find Full Text PDF

[An incidental atrial fibrillation. Is the best the enemy of good?].

Rev Med Suisse

August 2025

Service de cardiologie, HFR Fribourg - Hôpital cantonal, 1752 Villars-sur-Glâne.

Atrial fibrillation (AF) is common in the elderly and often incidental. While anticoagulation is facilitated by risk-stratification scores, rate versus rhythm-control in the elderly and likely asymptomatic population remain challenging. We report an 80-year-old male with newly diagnosed slow AF, referred for an electrical cardioversion after amiodarone loading.

View Article and Find Full Text PDF