A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Bioassay engineering: a combined label-free and fluorescence approach to optimize HER2 detection in complex biological media. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We report on the combined label-free/fluorescence use of one-dimensional photonic crystals to optimize cancer biomarker detection in complex biological media. The optimization of the assay working parameters permits us to maximize the final response of the biosensor. The detection approach utilizes a sandwich assay, in which one-dimensional photonic crystals sustaining Bloch surface waves are modified with monoclonal antibodies in order to guarantee high specificity during biological recognition. The multiple outcomes generated by such optimization experiments permitted us to determine the effective capture efficiency and the repeatability of the immobilization process, which was estimated to be close to 5%. By exploiting the resolution of the fluorescence operation mode, we studied non-specific interactions in different blocking agents, different analyte diluting buffers, and diverse concentrations of the detection antibody. As a clinically relevant biomarker, we selected the trans-membrane receptor tyrosine kinase HER2. HER2 regulates a variety of cell proliferation, growth, and differentiation pathways and its over-expression occurs in approximately 20-30% of breast cancer worldwide. As a final application, we transferred all the optimized working parameters to HER2 cancer biomarker assays in a complex biological environment. The label-free and fluorescence results obtained by analyzing MCF-7 (HER2 low positive) and 32D (HER2 negative) cell lysates demonstrate that we can successfully discriminate the two lysates.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-020-02643-3DOI Listing

Publication Analysis

Top Keywords

complex biological
12
label-free fluorescence
8
detection complex
8
biological media
8
one-dimensional photonic
8
photonic crystals
8
cancer biomarker
8
working parameters
8
her2
6
bioassay engineering
4

Similar Publications