A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Simulating Ultrasound Tissue Deformation Using Inverse Mapping. | LitMetric

Simulating Ultrasound Tissue Deformation Using Inverse Mapping.

J Comput Nonlinear Dyn

Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, 319 Leonhard Building, University Park, PA 16802.

Published: October 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ultrasound guidance is used for a variety of surgical needle insertion procedures, but there is currently no standard for the teaching of ultrasound skills. Recently, computer ultrasound simulation has been introduced as an alternative teaching method to traditional manikin and cadaver training because of its ability to provide diverse scenario training, quantitative feedback, and objective assessment. Current computer ultrasound training simulation is limited in its ability to image tissue deformation caused by needle insertions, even though tissue deformation identification is a critical skill in performing an ultrasound-guided needle insertion. To fill this need for improved simulation, a novel method of simulating ultrasound tissue-needle deformation is proposed and evaluated. First, a cadaver study is conducted to obtain ultrasound video of a peripheral nerve block. Then, optical flow analysis is conducted on this video to characterize the tissue movement due to the needle insertion. Tissue movement is characterized into three zones of motion: tissue near the needle being pulled, and zones above and below the needle where the tissue rolls. The rolling zones were centered 1.34 mm above and below the needle and 4.53 mm behind the needle. Using this characterization, a vector field is generated mimicking these zones. This vector field is then applied to an ultrasound image using inverse mapping to simulate tissue movement. The resulting simulation can be processed at 3.1 frames per second. This methodology can be applied through future optimized graphical processing to allow for accurate real time needle tissue simulation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7104777PMC
http://dx.doi.org/10.1115/1.4042809DOI Listing

Publication Analysis

Top Keywords

tissue deformation
12
needle insertion
12
tissue movement
12
tissue
9
needle
9
simulating ultrasound
8
inverse mapping
8
computer ultrasound
8
needle tissue
8
vector field
8

Similar Publications