Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: The sacroiliac joint is an important source of low back pain. In severe cases, sacroiliac joint fusion is used to reduce pain, but revision rates can reach 30%. The lack of initial mechanical stability may lead to pseudarthrosis, thus not alleviating the patient's symptoms. This could be due to the damage induced to the interosseous ligament during implant insertion. Decoupling instrumentation steps (drilling-tapping and implant insertion) would allow verifying this hypothesis. Moreover, no biomechanical studies have been published on sacroiliac joint fixation with an oblique lateral approach, while it has important clinical advantages over the direct lateral approach.
Methods: Eight cadaveric human pelves with both ischia embedded were tested in three sequential states: intact, drilled-tapped and instrumented with one cylindrical threaded implant with an oblique lateral trajectory. Specimens were assigned one of two insertion sites (distal point; near the posterior superior iliac spine, and proximal point; anterosuperior to the distal point) and tested in compression and flexion-extension. Vertical and angular displacements of the sacroiliac joint were measured locally using digital image correlation methods.
Findings: In compression, instrumentation significantly reduced vertical displacements (17% (SD 22%), P = 0.04) but no difference was found for angular displacements or flexion-extension loads (P > 0.05). Drilling-tapping did not change the stability of the sacroiliac joint (P > 0.05); there was no statistical difference between the insertion sites (P > 0.05).
Interpretations: Insertion of one implant through either the distal or proximal insertion site with an oblique lateral approach significantly reduced vertical displacements of the sacroiliac joint in compression, a predominant load of this joint.
Research Ethics Committee: Polytechnique Montreal: CÉR-1617-30.
Download full-text PDF |
Source |
---|---|