Comparison of Suture-Augmented Ligamentplasty to Transarticular Screws in a Lisfranc Cadaveric Model.

Foot Ankle Int

Clinica Alemana de Santiago-Universidad del Desarrollo, Santiago Metropolitan Region (RM), Chile.

Published: June 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Lisfranc injuries represent a spectrum of trauma from high-energy lesions, with significant instability of the midfoot, to low-energy lesions, with subtle subluxations or instability without gross displacement. Recently, treatment options that allow for physiologic fixation of this multiplanar joint are being evaluated. The purpose of this study was to analyze the stability of a cadaveric Lisfranc injury model fixed with a novel suture-augmented neoligamentplasty in comparison with a traditional transarticular screw fixation construct.

Methods: Twenty-four fresh-frozen, matched cadaveric leg and foot specimens (12 individuals younger than 65 years of age) were used for this study. Two different types of Lisfranc ligament injuries were tested: partial and complete. Two different methods of fixation were compared: transarticular screws and augmented suture ligamentplasty with FiberTape. Specimens were fixed to a rotation platform in order to stress the joints while applying 400 N of axial load and internal and external rotation. Six distances were measured and compared between the intact, injured, and fixed states with a 3D Digitizer arm, in order to evaluate the stability between them. Analysis of variance was used with < .05 considered significant.

Results: Using distribution graphs and analyzing the grouped data, it was observed that there was no difference between the 2 stabilization methods, but the augmented suture ligamentplasty presented lower variability and observed distance shortenings were more likely to be around the mean. The variability of the stabilization with screws was 2.9 times higher than that with tape ( < .001).

Conclusion: We suggest that augmented suture ligamentplasty can achieve similar stability to classic transarticular screws, with less variability.

Clinical Relevance: This cadaveric study adds new information on the debate about Lisfranc lesions treatment. Flexible fixations, such as the synthethic ligamentplasty used, can restore good stability such as conventional transarticular screws.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1071100720907878DOI Listing

Publication Analysis

Top Keywords

transarticular screws
16
augmented suture
12
suture ligamentplasty
12
ligamentplasty
5
transarticular
5
screws
5
lisfranc
5
comparison suture-augmented
4
suture-augmented ligamentplasty
4
ligamentplasty transarticular
4

Similar Publications

Purpose: To evaluate the safety and efficacy of modified cortical bone trajectory (MCBT) screw combined with transarticular screw (TASS) fixation (MCBT-TASS) in modified midline lumbar interbody fusion (M-MIDLIF) for single-level lumbar degenerative disease (LDD).

Methods: We retrospectively included 104 patients with L4-5 or L5-S1 single-segment LDD who had indications for decompression, fusion, and internal fixation surgery from 2019 to 2022. They were subsequently divided into M-MIDLIF and modified transforaminal lumbar interbody fusion (M-TLIF) groups according to the surgical approach.

View Article and Find Full Text PDF

Background And Objectives: Odontoid fractures are often managed surgically. The most common approaches are anterior dens screw (ADS) and posterior arthrodesis (PA), with the latter being associated with significantly higher fusion rates. PA techniques can include wiring, C1-C2 transarticular (TA) screws, and C1 lateral mass (LM)-C2 pars/pedicle screws.

View Article and Find Full Text PDF

This study aimed to compare the stress distribution in proximal interphalangeal joint arthrodesis with locking compression plate in horses based on the type and method of screw implantation in the proximal hole and partial or total removal of implants after fusion.Finite element analysis.Proximal interphalangeal joint arthrodesis was simulated using a 3-hole, 4.

View Article and Find Full Text PDF

Objective: Surgical fixation for occipitocervical instability can be challenging due to limitations in occipital instrumentation that include prominent hardware, limited fixation points on the occiput, and the risk of intracranial injury. Occipital instrumentation is particularly difficult in pediatric patients with thinner skull osteology and smaller bony surface area. Transarticular atlantooccipital and occipital condyle screw placement are newer techniques that have been described as alternative strategies for occipitocervical fixation.

View Article and Find Full Text PDF

Background: Intramedullary headless screw fixation has become significant in the treatment of phalangeal fractures. While intramedullary headless screw fixation is a simple and rigid approach, common techniques for guide wire insertion, including retrograde, antegrade-intra-articular, and trans-articular techniques, damage the articular cartilage and extensor tendon, particularly the central slip. To mitigate these risks, we applied a new method by percutaneously inserting the screw obliquely from the radial or ulnar base of the proximal or middle phalanges.

View Article and Find Full Text PDF