A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Self-assembly of pendant functional groups grafted PEDOT as paracetamol detection material. | LitMetric

Self-assembly of pendant functional groups grafted PEDOT as paracetamol detection material.

Phys Chem Chem Phys

Key Laboratory of Oil and Gas Fine Chemicals, Ministry of Education & Xinjiang Uygur Autonomous Region, Xinjiang University, Urumqi, 830046, P. R. China.

Published: February 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this paper, pendant functional group grafted EDOTs, such as EDOTCHNH, EDOTCHOH and EDOTCHSH, were selected as monomers for the preparation of their respective polymers via a common chemical oxidative polymerization method in the absence of CTAB by varying the [monomer]/[oxidant] ratios. The self-assembly mechanism of the polymers was systematically studied by discussing the hydrogen bonding effect, acidity and electron-donating ability, as well as the chain initiation and chain growth of the chemically oxidated polymerized monomers. These functional group grafted PEDOTs were applied to the electrochemical determination of paracetamol (PAR) to further investigate the effect of the pendant functional groups (-SH, -OH, -NH) on the electrochemical sensing behaviour of the polymers. The results indicated that the hydrogen bonding effect of the pendant functional groups was vital to the self-assembly of the polymer chains, and the PEDOTs with -OH and -SH groups had a tendency to self-assemble into a spherical structure, while the PEDOT with an -NH group exhibited a fibrous structure. The electrochemical response of PEDOTs with functional groups was better than that that of PEDOT alone, and the highest electrochemical response was observed in PEDOT with an -SH group ([monomer]/[oxidant] = 1 : 8).

Download full-text PDF

Source
http://dx.doi.org/10.1039/c9cp05759eDOI Listing

Publication Analysis

Top Keywords

pendant functional
16
functional groups
16
functional group
8
group grafted
8
hydrogen bonding
8
electrochemical response
8
functional
6
groups
5
self-assembly pendant
4
groups grafted
4

Similar Publications