Article Abstract

To describe our endoscopic aortic valve replacement (E-AVR) technique and to evaluate its early results regardless of the type of prosthetic valve implanted and the patients' characteristics. From July 2013 to September 2018, 125 patients (76 males, mean age 68.8 ± 10.9 years, mean EuroScore II 1.51 ± 1.39) underwent isolated E-AVR due to a severe stenosis in 99 cases and insufficiency in 26 cases. The surgical access was a 3-4 cm working port in the second right intercostal space with no rib-spreading and 3 additional 5 mm miniports for the introduction of a 30-degree thoracoscope, the Chitwood clamp, and the vent line. Cardiopulmonary bypass (CPB) was achieved through a femoro-femoral cannulation. All patients successfully underwent E-AVR. Stended bioprostheses were implanted in 56 cases, Rapid Deployment and Sutureless valves in 23 and 46 cases, respectively. Mean cross-clamping and CPB times were 87.5 ± 22.1 and 126.1 ± 28.4 minutes, respectively, and a significant difference between the types of prostheses was observed: 69.1 ± 15.1 and 106.2 ± 21.8 minutes (Sutureless) vs 93.2 ± 15.1 and 135.5 ± 21.8 minutes (Rapid Deployment) vs 100.6 ± 17.2 and 138.9 ± 21.9 minutes (Stented). Mean ventilation and ICU times and hospital stay were 10.9 ± 39.3 hours, 45.9 ± 58.4 hours, and 8.3 ± 9.3 days, respectively. Thirty-day mortality was 0.8%. One patient (0.8%) needed a re-exploration for bleeding and 3 patients (2.4%) required a new permanent pacemaker implantation. No major neurologic events were observed. No paravalvular leakage was detected at discharge. E-AVR is associated with low mortality and few complications. Sutureless bioprostheses significantly reduce cross-clamping and CPB times. In dedicated centers, this approach may become a valid alternative to other minimally invasive techniques.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.semtcvs.2020.01.002DOI Listing

Publication Analysis

Top Keywords

minimally invasive
8
endoscopic aortic
8
aortic valve
8
valve replacement
8
rapid deployment
8
cross-clamping cpb
8
cpb times
8
± 218 minutes
8
invasive endoscopic
4
replacement operative
4

Similar Publications

Objective: To describe the long-term outcome of a horse that underwent a standing, ultrasound-guided, minimally invasive, biceps brachii tenotomy.

Study Design: Case report.

Animal: A 17-year-old Tennessee Walking Horse gelding.

View Article and Find Full Text PDF

Robotic mitral repair is often associated with longer ischaemic and cardiopulmonary bypass times, particularly early in the learning curve. We demonstrate a semi-continuous, three-suture technique for robotic annuloplasty that retains the mechanical principles of traditional interrupted sutures while leveraging the advantages of robotic precision and exposure. The use of pre-knotted sutures minimizes intra-cardiac knot tying, further enhancing procedural efficiency.

View Article and Find Full Text PDF

Cystic lesions of the head and neck encompass a wide spectrum of benign and malignant entities, which often presents diagnostic challenges as a result of the region's complex anatomy. Despite extensive literature, variability persists in diagnostic strategies and approaches. Fine-needle aspiration biopsy is a commonly used and highly effective method for the initial assessment of these lesions by offering a minimally invasive technique to collect cellular material for diagnostic evaluation.

View Article and Find Full Text PDF

Minimally invasive surgical approaches for pneumothorax: evolution and current perspectives.

Expert Rev Respir Med

September 2025

Department of General Thoracic Surgery, Social Welfare Organization Saiseikai Imperial Gift Foundation, Chibaken Saiseikai Narashino Hospital, Chiba, Japan.

Introduction: PubMed was used for a literature search (1990-2025) on the minimally invasive surgical approaches for pneumothorax, which have evolved markedly, with video-assisted thoracic surgery (VATS) emerging as a preferred procedure. Systematic reviews of randomized control trials indicate that VATS is less invasive than traditional thoracotomy. Furthermore, uniportal VATS provides less postoperative pain and better cosmetic outcomes than thoracotomy.

View Article and Find Full Text PDF

Endothelial Colony-Forming Cells (ECFCs) are recognized as key vasculogenic progenitors in humans and serve as valuable liquid biopsies for diagnosing and studying vascular disorders. In a groundbreaking study, Anceschi et al. present a novel, integrative strategy that combines ECFCs loaded with gold nanorods (AuNRs) to enhance tumor radiosensitization through localized hyperthermia.

View Article and Find Full Text PDF