A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

HEMOGLOBIN WAYNE VARIANT INTERFERING WITH HEMOGLOBIN A1C MEASUREMENT. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To describe the effect of hemoglobin Wayne variant on hemoglobin A1c (A1c) accuracy and to stress the importance of patient-physician communication and trust.

Methods: We present the clinical history and laboratory findings of 2 patients, with a review of related literature.

Results: Two older patients were diagnosed with diabetes mellitus (DM) and suffered from frequent hypoglycemia resulting from titrating their diabetes medications based on an extremely elevated A1c (>11% [97 mmol/mol]) obtained through high-performance liquid chromatography. Discrepancies were noticed between their blood glucose logs and their A1c results. Ultimately, both were found to have heterogenous hemoglobin Wayne variant by hemoglobin electrophoresis. Repeat immunoassay found the A1c to be very low, in the 5 to 6.2% (31 to 44 mmol/mol) range. One of the patients did not even meet diagnostic criteria for DM.

Conclusion: A1c testing is susceptible to misinterpretation due to multiple interfering factors. Hemoglobin variants should be considered as a differential when there are discrepancies between A1c and blood glucose levels. Trust between the patient and the physician is essential in raising clinical suspicion and avoiding potentially lethal outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6876977PMC
http://dx.doi.org/10.4158/ACCR-2018-0017DOI Listing

Publication Analysis

Top Keywords

hemoglobin wayne
12
wayne variant
12
a1c
8
hemoglobin a1c
8
variant hemoglobin
8
blood glucose
8
hemoglobin
7
variant interfering
4
interfering hemoglobin
4
a1c measurement
4