98%
921
2 minutes
20
This study identifies general characteristics of methods to estimate the absolute range between an acoustic transmitter and a receiver in the deep ocean. The data are from three days of the PhilSea10 experiment with a single fixed transmitter depth (∼998 m) and 150 receiver depths (∼210-5388 m) of known location, and a great-circle transmitter-receiver distance of ∼510 km. The proposed ranging methods compare observed acoustic records with synthetic records computed through the HYCOM (hybrid coordinate ocean model) model. More than 8900 transmissions over 3 days characterize the statistical variation of range errors. Reliable ranging methods de-emphasize the parts of the data records least likely to be reproduced by the synthetics, which include arrival amplitudes, the later parts of the acoustic records composed of nearly horizontally launched rays (i.e., the finale), and waves that sample a narrow span of ocean depths. The ranging methods proposed normalize amplitudes, measure travel times, or reject parts of the waveforms beyond a critical time. All deliver reliable range estimates based on the time and path-averaged HYCOM model, although the final method performs best. The principles behind these methods are transportable and expected to provide reliable range estimates in different deep water settings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/1.5138606 | DOI Listing |
J Adv Nurs
September 2025
Department of Internal Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
Aims: To assess self-reported practices and knowledge of nurses and prescribers (i.e., physicians and nurse practitioners) on intravenous fluid therapy, and to evaluate how this is documented through a clinical documentation review.
View Article and Find Full Text PDFVet Ophthalmol
September 2025
Ophthalmology Section, Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
Objective: To describe the use of transcorneal iris photocoagulation (TCIP) to improve intraocular visualization of intended incision lines, reduce hemorrhage, and facilitate excision of pigmented iridal tumors in four canine eyes and one feline eye.
Materials And Methods: A Rhodesian Ridgeback (treated bilaterally), a German Shepherd, a Labrador Retriever, and a Scottish Fold underwent sector iridectomy due to rapidly growing, pigmented, raised, iridal tumors affecting 1/4-1/3 of the iris circumference (3- to 4-clock hours). A diode laser was used to delineate the intended sector iridectomy incision lines, approximately 1-2 mm away from the grossly visible tumor margins, with the aim of improving visualization to achieve tumor-free margins and reduce tissue handling/trauma.
Neurorehabil Neural Repair
September 2025
Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, UK.
Background: Gait impairment in Parkinson's disease (PD) occurs early and pharmaceutical interventions do not fully restore this function. Visual cueing has been shown to improve gait and alleviate freezing of gait (FOG) in PD. Technological development of digital laser shoe visual cues now allows for visual cues to be used continuously when walking.
View Article and Find Full Text PDFAnal Methods
September 2025
Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran.
This study introduces a new, highly sensitive, and reliable method for detecting and measuring orthophosphate in environmental water samples. This method combines cetyltrimethylammonium bromide (CTAB)-mediated coacervation extraction with digital image-based colorimetry, providing a robust and efficient approach for orthophosphate analysis. In this system, CTAB, a cationic surfactant, serves a dual role as both an ion-pairing agent and an extraction medium.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
September 2025
Department of Congenital Heart Disease, Evelina London Children's Hospital, United Kingdom (S. Chivers, T.V., V.Z., S.M., G.M., W.R., E.R., D.F.A.L., T.G.D., O.I.M., G.K.S., J.M.S.).
Background: Fetal tachycardias can cause adverse fetal outcomes including ventricular dysfunction, hydrops, and fetal demise. Postnatally, ECG is the gold standard, but, in fetal practice, echocardiography is used most frequently to diagnose and monitor fetal arrhythmias. Noninvasive extraction of the fetal ECG (fECG) may provide additional information about the electrophysiological mechanism and monitoring of intermittent arrhythmias.
View Article and Find Full Text PDF