Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Microporous organic network (MON) is a promise class of functional materials in solid phase extraction (SPE). However, the previous MON-based SPE works are all focused on off-line mode. The inherent drawbacks of off-line SPE such as complicated operation steps and poor repeatability still hinder the potential applications of MON. In addition, direct use of traditional synthesized nano-sized MON in on-line SPE is impractical. To solve these issues, here we show the synthesis of silica amino-functionalized MON (SiO@MON-NH) microsphere as an advanced adsorbent for on-line SPE of trace phenols prior to the high performance liquid chromatography (HPLC) analysis. The SiO microsphere is served as the core to support the in-situ engineering of MON-NH to reduce the back pressure during on-line SPE. Integrating amino groups (hydrogen binding sites) with aromatic MON's networks (hydrophobic and π-π interaction sites) on SiO@MON-NH provides supersensitive performance for phenols. The SiO@MON-NH microsphere for on-line SPE coupled with HPLC for the analysis of five phenols offers low limit of detections (S/N = 3, 0.009-0.030 μg L), wide linear range (0.025-100 μg L), large enrichment factors (5036-5689) and good intra-day and inter-day precisions (RSDs, 0.7-1.6 and 1.0-2.7%, respectively). The proposed method is also successfully applied to analyze trace phenols in tap, lake and river water samples with good recoveries. The newly-synthesized MON composites own great potential in on-line SPE for further determination of diverse trace contaminants.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2019.460791 | DOI Listing |