Background: The definite treatment of pelvic C fractures presents a widely discussed issue and undergoes continuous evolution. While the stabilization of the posterior ring has been studied extensively, the fixation of the anterior pelvic ring continuous to be rarely investigated. The importance of the simultaneous stabilization however lays in the earlier mobilization and prevention of long-term damage to the pelvis. Therefore we investigated four combinations of minimally invasive fixation techniques for unstable type C1-3 pelvic injuries and aimed to answer the following research questions: (1) what combination of fixation methods yields the highest stiffness and the least displacement? (2) Is the combination of a single sacroiliac screw (SI-screw) with a transiliac internal fixator (TIFI) a reasonable alternative to two SI-screws? (3) Is a modified unilateral anterior fixation comparable to a retrograde transpubic screw?

Hypothesis: Minimally invasive fixation techniques provide sufficient biomechanical stability for type C pelvic fractures.

Methods: Thirty synthetic full pelvises were divided into 5 groups, of which 4 groups were assigned a different osteosynthesis method and one was an intact pelvis used as reference (group 1: internal fixator+2 sacroiliac screws, group 2: internal fixator+transiliac internal fixator+1 sacroiliac screw, group 3: retrograde transpubic screw+2 sacroiliac screws, group 4: retrograde transpubic screw+transiliac internal fixator+1 sacroiliac screw). The pelvises underwent a protocol of cyclic loading between 100N and 200N, during which they were subjected to compression loads while the position of the fracture fragments was measured every 30 milliseconds. Displacement and stiffness were calculated for statistical analysis.

Results: The minimally invasive fixation methods investigated in this study all provide sufficient biomechanical stability without one method being superior to the others (p [anterior displacement]=0.61 and p [posterior displacement]=0.88). Group 3 was allowed the least displacement (1.8±0.2mm for anterior and posterior fracture) for the treatment of a C1.3 fracture. The other fixation methods displayed the following dislocations (mm) of the anterior pelvic ring: group 1: 1.9±0.3, group 2: 2.1±0.4, group 4: 2.0±0.5. Posteriorly, the displacements (mm) were the following: group 1: 1.8±0.6, group 2: 1.9±0.2, group 4: 2.0±0.5.

Discussion: The minimally invasive fixation methods investigated in this study all provide sufficient biomechanical stability without one method being superior to the others since differences were not significant regarding anterior and posterior displacements. Even if not significantly, we could reveal that out of all the methods tested the combination of 2 SI-screws with a retrograde transpubic screw (group 3) displayed the least displacement and highest stiffness. These techniques could therefore potentially improve patient's clinical outcome by reducing the surgical invasiveness and procedure time while providing sufficient biomechanical stability.

Level Of Evidence: III, comparative in vitro study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2019.09.032DOI Listing

Publication Analysis

Top Keywords

minimally invasive
20
invasive fixation
16
fixation methods
16
retrograde transpubic
16
sufficient biomechanical
16
pelvic ring
12
sacroiliac screw
12
provide sufficient
12
biomechanical stability
12
group
12

Similar Publications

Objective: To investigate the prognostic significance of concurrent monitoring of serum S100 calcium-binding protein A12 (S100A12) and optic nerve sheath diameter (ONSD) in patients with traumatic intracranial hematoma.

Methods: This prospective observational study included 198 patients with traumatic intracranial hematoma from Xingtai Central Hospital (February 2022-June 2024). Serum S100A12 and ONSD were measured at admission and postoperatively, and patients received minimally invasive therapy.

View Article and Find Full Text PDF

Background: Spleen-preserving distal pancreatectomy by robotic surgery is a safe and feasible surgical technique. Currently, spleen-preserving distal pancreatectomy represents an alternative to the classical distal pancreatectomy with splenectomy, in the case of benign and low-grade malignant diseases of the body or pancreas tail. The reasons for preserving the spleen are based on the reduction of postoperative complications, such as post-splenectomy infections, subphrenic abscess, portal thrombosis, pulmonary hypertension, thrombocytosis, and thromboembolism.

View Article and Find Full Text PDF

Robotic surgery has transformed the field of surgery, offering enhanced precision, minimal invasiveness, and improved patient outcomes. This narrative review explores the multifaceted aspects of robotic surgery, examining the challenges, recent advances, and future prospects for its integration into healthcare. Our comprehensive analysis of 48 studies reveals significant geographic disparities in robotic surgery research and implementation, with 68.

View Article and Find Full Text PDF

Purpose: This meta-analysis compares thoracoscopic versus open thoracotomy repair of esophageal atresia with tracheoesophageal fistula (EA/TEF).

Methods: We systematically searched PubMed, Web of Science, Cochrane Library, and Scopus from inception to April 2025 for studies comparing thoracoscopic versus conventional thoracotomy approaches. Two independent reviewers screened studies, extracted data, and assessed risk of bias using appropriate tools.

View Article and Find Full Text PDF

Long-term complications in patients with bladder-prostate rhabdomyosarcoma treated with brachytherapy: a systematic review.

Pediatr Surg Int

September 2025

Pediatric Surgery Unit, Department of Women's and Children's Health, University of Padua, Via Nicolò Giustiniani, 35100, Padua, Italy.

Introduction: Brachytherapy has been used for the multimodal treatment of pediatric bladder-prostate rhabdomyosarcoma in the last two decades. The aim of this systematic review is to gather the current evidence about this innovative technique with a special focus on long-term outcomes.

Methods: According to PRISMA criteria, PubMed, Scopus, and Web of Science were searched for papers published between 2000 and 2022.

View Article and Find Full Text PDF