98%
921
2 minutes
20
Phase difference measurement of sinusoidal signals can be used for phase error calibration of the spaceborne single-pass interferometric synthetic aperture radar (InSAR) system. However, there are currently very few papers devoted to the discussion of phase difference measurement of high-frequency internal calibration signals of the InSAR system, especially the discussion of sampling frequency selection and the corresponding measuring method when the high-frequency signals are sampled under the under-sampling condition. To solve this problem, a phase difference measurement method for high-frequency sinusoidal signals is proposed, and the corresponding sampling frequency selection criteria under the under-sampling condition is determined. First, according to the selection criteria, the appropriate under-sampling frequency was chosen to sample the two sinusoidal signals with the same frequency. Then, the sampled signals were filtered by limited recursive average filtering (LRAF) and coherently accumulated in the cycle of the baseband signal. Third, the filtered and accumulated signals were used to calculate the phase difference of the two sinusoidal signals using the discrete Fourier transform (DFT), digital correlation (DC), and Hilbert transform (HT)-based methods. Lastly, the measurement accuracy of the three methods were compared respectively by different simulation experiments. Theoretical analysis and experiments verified the effectiveness of the proposed method for the phase error calibration of the InSAR system.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6929184 | PMC |
http://dx.doi.org/10.3390/s19235328 | DOI Listing |
Adv Ther
September 2025
Petauri Evidence, Nottingham, UK.
Introduction: Hemophilia A, an X-linked recessive bleeding disorder, is characterized by reduced factor VIII (FVIII) activity. Hemophilia A can significantly impact a person's quality of life because of the risk of spontaneous bleeding. Treatment for hemophilia A aims to prevent bleeding from occurring.
View Article and Find Full Text PDFACS Appl Mater Interfaces
September 2025
Department of Chemistry, University of Wisconsin-Madison, 1101 University Ave., Madison, Wisconsin 53706, United States.
Slippery liquid-infused porous surfaces (or "SLIPS") can prevent bacterial surface fouling, but they do not inherently possess the means to kill bacteria or reduce cell loads in surrounding media. Past reports show that the infused liquids in these materials can be leveraged to load and release antimicrobial agents, but these approaches are generally limited to the use of hydrophobic agents that are soluble in the infused oily phases. Here, we report the design of so-called "proto-SLIPS" that address this limitation and permit the release of highly water-soluble (or oil-insoluble) agents.
View Article and Find Full Text PDFClin Pharmacol Drug Dev
September 2025
Phase I Clinical Research Centre, Wuhan Pulmonary Hospital, Wuhan, China.
Tamsulosin is a highly selective α1A adrenergic receptor antagonist that can relax smooth muscles in the urethra, bladder neck, and prostate and improve urinary disorders. It is therefore widely used to treat lower urinary tract symptoms caused by benign prostatic hyperplasia. The aim of this study is to evaluate the pharmacokinetic (PK) characteristics and bioequivalence of 2 different formulations (tamsulosin sustained-release tablets and tamsulosin sustained-release capsules) in healthy Chinese subjects.
View Article and Find Full Text PDFMicrosc Res Tech
September 2025
Department of Physics, West Tehran Branch, Islamic Azad University, Tehran, Iran.
Titanium dioxide (TiO) thin films were deposited on glass substrates under HV conditions at room temperature by the physical vapor deposition method. Produced titanium thin films were post-annealed at 573 K at different oxygen flows (0, 9 and 23 cm/s). The influence of different oxygen flows on nano-structure, crystallography, and optical parameters of TiO films was investigated by XRD, AFM, and spectrophotometer in the UV-VIS wavelength range.
View Article and Find Full Text PDFAdv Sci (Weinh)
September 2025
Department Chemie- und Bioingenieurwesen, Lehrstuhl für Chemische Reaktionstechnik (CRT), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Egerlandstr. 3, 91058, Erlangen, Germany.
The supported catalytically active liquid metal solution (SCALMS) concept is based on catalytically active metals dissolved in a low-melting-point liquid metal matrix. These solid alloy particles, deposited over a high area support, transform into a liquid alloy under reaction conditions. In this work, GaPt SCALMS materials of varying composition are investigated and focus on the change in the alloy composition during preheating, the actual high temperature propane dehydrogenation at 823 K, and after cool-down.
View Article and Find Full Text PDF