Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Sink drainage systems are not amenable to standard methods of cleaning and disinfection. Disinfectants applied as a foam might enhance efficacy of drain decontamination due to greater persistence and increased penetration into sites harboring microorganisms.

Objective: To examine the efficacy and persistence of foam-based products in reducing sink drain colonization with gram-negative bacilli.

Methods: During a 5-month period, different methods for sink drain disinfection in patient rooms were evaluated in a hospital and its affiliated long-term care facility. We compared the efficacy of a single treatment with 4 different foam products in reducing the burden of gram-negative bacilli in the sink drain to a depth of 2.4 cm (1 inch) below the strainer. For the most effective product, the effectiveness of foam versus liquid-pouring applications, and the effectiveness of repeated foam treatments were evaluated.

Results: A foam product containing 3.13% hydrogen peroxide and 0.05% peracetic acid was significantly more effective than the other 3 foam products. In comparison to pouring the hydrogen peroxide and peracetic acid disinfectant, the foam application resulted in significantly reduced recovery of gram-negative bacilli on days 1, 2, and 3 after treatment with a return to baseline by day 7. With repeated treatments every 3 days, a progressive decrease in the bacterial load recovered from sink drains was achieved.

Conclusions: An easy-to-use foaming application of a hydrogen peroxide- and peracetic acid-based disinfectant suppressed sink-drain colonization for at least 3 days. Intermittent application of the foaming disinfectant could potentially reduce the risk for dissemination of pathogens from sink drains.

Download full-text PDF

Source
http://dx.doi.org/10.1017/ice.2019.325DOI Listing

Publication Analysis

Top Keywords

sink drain
12
effectiveness foam
8
products reducing
8
foam products
8
gram-negative bacilli
8
hydrogen peroxide
8
peracetic acid
8
sink drains
8
foam
7
sink
6

Similar Publications

Rewetting drained peatland forests restores pristine ecosystem functions, improves peatland ecological status, and has been considered to mitigate climate change. We quantified climate impact of rewetting boreal peatland forests in Northern Europe by comparing the radiative forcing of alternative restoration pathways to that of continued forestry use. We considered changes in soil carbon dioxide, methane and nitrous oxide balance, tree stand carbon sink-source dynamics, albedo change, and included the wood product carbon storage and release.

View Article and Find Full Text PDF

Boreal peatlands strongly affect the global climate system by providing an important store for carbon (C) cycle and a natural source of methane. Over the past century, however, vast areas of natural peatlands have been drained to gain productive land, turning them into large potential C sources. Currently, there is a scientific debate on how to best manage historically drained boreal peatlands to improve their function in climate change mitigation.

View Article and Find Full Text PDF

Hidden transmissions of Pseudomonas aeruginosa ST111 -the importance of continuous molecular surveillance.

Antimicrob Resist Infect Control

August 2025

Department for Infection Prevention and Control, Institute for Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.

Background: A series of transmission of Pseudomonas aeruginosa ST111 bla, previously undetected by standard surveillance, was discovered in a tertiary care hospital in Northern Germany through molecular genetic monitoring. Hence, environmental sampling was initiated to find the source of infection.

Methods: First, routine epidemiological data ruled out patient-to-patient transmission and two initial diagnoses were assessed as externally acquired.

View Article and Find Full Text PDF

Background: There is growing evidence for the involvement of sink and wash-hand basin traps in the spread of hospital-acquired infections in clinical settings. This Pilot Study used a full-scale model of a hospital wash-hand basin and wastewater drainage system, typical in single-occupancy hospital bathrooms, to examine bacterial transmission from sink traps to wash-hand basins during drainage system air pressure surges.

Methods: Simulating real-world conditions in a laboratory, a 50-metre pipe network was connected to the model en-suite bathroom.

View Article and Find Full Text PDF

Protracted outbreaks of VIM-producing Pseudomonas aeruginosa in a surgical intensive care unit in France, January 2018 to June 2024.

Antimicrob Resist Infect Control

August 2025

Unité de Prévention du Risque Infectieux, Hôpital Saint-Antoine, Assistance Publique-Hôpitaux de Paris, Paris, France.

Background: Pseudomonas aeruginosa is frequently responsible for hospital-acquired infections. It may be isolated in healthcare environment where it can survive. Between January 2018 and June 2024, a growing number of VIM-producing Pseudomonas aeruginosa (PA-VIM) were isolated from patients hospitalized in our surgical intensive care unit (SICU).

View Article and Find Full Text PDF