A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

High-Throughput UHPLC-MS/MS Measurement of Per- and Poly-Fluorinated Alkyl Substances in Human Serum. | LitMetric

High-Throughput UHPLC-MS/MS Measurement of Per- and Poly-Fluorinated Alkyl Substances in Human Serum.

J Anal Toxicol

Division of Cardiovascular Medicine, The Gill Heart and Vascular Institute, Superfund Research Center and Center for Appalachian Research in Environmental Sciences, University of Kentucky College of Medicine, Lexington Veterans Affairs Medical Center, Lexington, KY 40536, USA.

Published: May 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Per- and poly-fluorinated alkyl substances (PFASs) are a large group of synthetic surfactant chemicals with widespread uses in food packaging and textile manufacturing and as the main constituent of aqueous film-forming firefighting foams. PFASs are highly persistent in the environment, and human exposures are extensive with these chemicals detectable in the blood of almost all adult Americans. PFASs exhibit a range of toxic effects in preclinical models. In humans, PFAS exposure has been associated with lower birth weights, decreased immune responses, cancer and impaired fertility and elevated circulating cholesterol levels. We have developed a sensitive high-throughput method for quantification of representative PFAS in human serum and plasma for biomonitoring and epidemiological studies of human health effects of PFAS exposure. The method combines robust and reproducible 96-well plate format sample preparation with ultra-performance liquid chromatography-tandem mass spectrometry. The method was developed, validated and used for targeted measurements of eight short-/long-chain PFAS analytes in human serum. Targeted analytes were measured in 50 microliters of sample using mass-labeled internal standards. Mean spiked recoveries (n = 10) of target analytes for three tiers quality control (QC-low, QC-medium, QC-high) samples ranged from 70 to 127% with 2-14% relative standard deviation (RSD). The average spiked recoveries (n = 10) of surrogates were 79-115% with 8-12% RSD for QC-low, 90-123% with 7-12% RSD for QC-medium and 82-114% with 9-15% RSD for QC-high. The limit of detection for the target compounds was 0.05-0.04 ng/mL. The method was used to reveal regional differences in PFAS exposures in Kentucky residents receiving care at the University of Kentucky Hospitals.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7299301PMC
http://dx.doi.org/10.1093/jat/bkz097DOI Listing

Publication Analysis

Top Keywords

human serum
12
per- poly-fluorinated
8
poly-fluorinated alkyl
8
alkyl substances
8
pfas exposure
8
spiked recoveries
8
recoveries n = 10
8
human
5
pfas
5
high-throughput uhplc-ms/ms
4

Similar Publications