Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: To identify factors predicting corneal astigmatic change following suture removal in post-penetrating keratoplasty patients.
Patients And Methods: This cross-sectional study included the data of 33 events of corneal suture removal from 27 post-penetrating keratoplasty patients. Sutures were removed from the steep axis of transplanted cornea with 16 interrupted corneal sutures. Corneal astigmatism was measured before and after suture removal using ORBSCAN II. Patients' demographic data and corneal biomechanics parameters obtaining from the Corvis ST were recorded. The changes in corneal astigmatism were calculated using vector analysis. The correlation between changes in corneal astigmatism and the potential factors was evaluated using Spearman's correlation coefficient and linear regression model.
Results: The mean corneal astigmatism before and after suture removal was 7.1±3.7 diopters (D) and 5.5±3.2D, respectively. The mean astigmatic change was 7.0±6.3D (range, 0.3-30.8D) by vector analysis at 9.7±5.5 weeks after suture removal. Change in corneal astigmatism was significantly correlated with pre-suture removal astigmatism (Rs=0.47, =0.01). There was no correlation between the donor-recipient trephine diameter difference, the duration from corneal transplantation to suture removal, the number of removed sutures with the change in corneal astigmatism, and corneal biomechanics parameters (>0.05). Linear regression is given by the following equation: astigmatic change (D)=1.05x pre-suture removal astigmatism (D) - 0.43.
Conclusion: The astigmatic change after corneal suture removal in post-keratoplasty patients was significantly correlated with pre-suture removal astigmatism. These findings will permit a validated approach for reducing corneal astigmatism in post-keratoplasty patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6709029 | PMC |
http://dx.doi.org/10.2147/OPTH.S213470 | DOI Listing |