98%
921
2 minutes
20
Introduction: A kinematic measurement method combining dynamic motion and imaging, which captures the behaviour of the hip at terminal motion, may offer improved diagnostic accuracy and enhance our understanding of the mechanics of femoroacetabular impingement (FAI).
Methods: 3 embalmed cadaveric hip/pelvis specimens with implanted Roentgen Stereophotogrammetric Analysis (RSA) beads were mounted on a custom rig and imaged with a fluoroscope in four poses to simulate a clinical impingement examination: in hip extension and in three positions: near impingement, early impingement and late impingement while simulating a flexion/adduction/internal rotation manoeuvre. Hip joint kinematics were measured using 2 methods and compared: RSA (gold standard) and a custom 3-dimensional to 2-dimensional (3D-2D) image registration method which matches 3D models developed from CT to 2D fluoroscopic images.
Results: Using RSA as the gold standard, bias and precision of hip joint rotations measured using 3D-2D registration demonstrated maximums of 1.64° and 3.96°, respectively. However, if the single outlier was removed, bias and precision were 0.55° and 1.38°. Bias and precision of translations had maximums of 0.51 mm and 0.77 mm, respectively.
Conclusions: This 3D to 2D registration method may offer a clinically useful solution for dynamic assessment of hip impingement. If 5-mm translation and 10° of rotation represent a clinically significant difference in hip kinematics, the method's accuracy of approximately 1 mm displacement and 1° rotation should enable detection of significant clinical differences.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/1120700019883548 | DOI Listing |
Arch Orthop Trauma Surg
September 2025
Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Background: Differentiating periprosthetic joint infections (PJI) from aseptic failure is challenging in total joint arthroplasty. To date, there is no consensus about the most accurate criteria to diagnose PJI. The current study compares common diagnostic PJI criteria.
View Article and Find Full Text PDFJ Am Acad Orthop Surg Glob Res Rev
September 2025
From the American Hip Institute Research Foundation (Dr. Quesada-Jimenez, Dr. Kahana-Rojkind, and Dr. Domb), and the American Hip Institute, Chicago, IL (Dr. Domb).
Hip pain after a total hip arthroplasty is a prevalent condition. Once aseptic loosening and infection have been ruled out, the possible entities are vast. Accurate diagnosis in this patient population is challenging because they might present in different stages of their recovery process and the potential overlap of some conditions.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
September 2025
Institute of Movement Sciences, Sainte-Marguerite Hospital, Aix-Marseille University, Marseille, France.
Purpose: This study aimed to evaluate the functional and radiological outcomes, complications and procedure survival in patients with posttraumatic tibial plateau deformities treated with unicondylar intra-articular tibial plateau osteotomy (UIATPO), comparing medial and lateral approaches.
Methods: A retrospective study was conducted on all patients with posttraumatic intra-articular tibial plateau deformities who underwent surgical correction at a single centre between 2016 and 2022, with a minimum follow-up of 24 months. Patient characteristics, radiological correction, patient-reported outcome measures (PROMs), including the Lysholm and knee injury and osteoarthritis outcome score (KOOS), and complications were recorded.
Knee Surg Sports Traumatol Arthrosc
September 2025
Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, Lyon, France.
Purpose: Robotic-assisted lateral unicompartmental knee arthroplasty (UKA) remains technically demanding due to the complex biomechanics of the lateral compartment. Image-based (IBRA) and imageless (ILRA) robotic systems have both demonstrated superior accuracy compared to conventional mechanical instrumentation, but have not yet been directly compared in lateral UKA. This study aimed to evaluate their respective accuracy and surgical efficiency.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
September 2025
University Clinic for Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, Switzerland.
Kinematic alignment is increasingly adopted in total knee arthroplasty (TKA) as a patient-specific strategy to restore native joint anatomy. However, its reliance on static radiographic measurements may not adequately reflect real-world functional biomechanics. This editorial underscores the importance of complementing static assessment with kinetic principles.
View Article and Find Full Text PDF