98%
921
2 minutes
20
Bone conduction implants based on percutaneous abutment acoustic transmission have been implemented in patients with satisfactory outcomes. However, adverse soft tissue outcomes present a limitation. Transcutaneous bone conduction devices (t-BCDs) are an alternative that may mitigate these complications. A retrospective review was performed of patients who underwent implantation of a t-BCD from 2013 to 2017. Surgical outcomes were reviewed including wound complications, frequency of device use, patient concerns regarding the device, and reported patient satisfaction. A total of 37 patients were implanted with the bone-anchored hearing aids, BAHA Attract (Cochlear™ Baha® Implant System). Average follow-up time was 271.8 days. Postoperatively, 7 (18.9%) patients complained of soft tissue changes or issues with wound healing. Twelve (32.4%) patients requested adjustment of their devices. The t-BCD is an excellent option for hearing rehabilitation. Overall, the complication rate is low, patient satisfaction is high, and successful conversion from a percutaneous device is possible with minimal risk.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0145561319870481 | DOI Listing |
Allergol Int
September 2025
Department of Otolaryngology/Deafness and Middle Ear Surgicenter, Tokyo Kita Medical Center, Tokyo, Japan; Department of Otolaryngology - Head and Neck Surgery, Jichi Medical University Saitama Medical Center, Saitama, Japan.
Background: Eosinophilic otitis media (EOM) is characterized by eosinophilic infiltration of the middle ear; it is frequently associated with bronchial asthma and chronic rhinosinusitis with nasal polyposis. Although biologics have been used to treat EOM, their efficacy based on clinical characteristics remains unclear. In this study, we evaluated the effectiveness of biologics and analyzed the clinical factors that influenced outcomes.
View Article and Find Full Text PDFIntroduction: The ADHEAR is a non-surgical Bone Conduction Device (BCD) that makes use of an adhesive adapter. While clinical trials have demonstrated its efficacy with regards to audiological performance, safety and compliance, data on real-world paediatric cohorts is scarce.
Methods: This retrospective cohort study analysed data from paediatric patients fitted with ADHEAR at a tertiary centre between January 2017 and September 2024.
Am J Case Rep
September 2025
Oto-Rhino-Laryngology Surgery Clinic, Institute of Physiology and Pathology of Hearing - World Hearing Center, Kajetany, Poland.
BACKGROUND Duplicated internal auditory canal (dIAC) is a rare congenital temporal bone anomaly associated with ipsilateral sensorineural hearing loss (SNHL). The Bonebridge bone conduction implant has a magnet, an internal transducer, and an external audio processor. This report is of a 14-year-old girl with unilateral SNHL and vestibulocochlear nerve (VIII cranial nerve) aplasia due to dIAC who was treated with a Bonebridge bone conduction implant.
View Article and Find Full Text PDFAuris Nasus Larynx
September 2025
Department of Otolaryngology-Head and Neck Surgery, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
A cartilage-conduction hearing aid (CCHA) transmits sound vibrations to the inner ear via the ear cartilage rather than through air or bone. They can be used in patients with meatal atresia and persistent otorrhea. Unlike bone-conduction hearing aid (BCHA), there is no need for pressure between the transducer and the temporal bone.
View Article and Find Full Text PDF