A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Optimization of the harvesting and freezing conditions of human cell lines for DNA damage analysis by the alkaline comet assay. | LitMetric

Optimization of the harvesting and freezing conditions of human cell lines for DNA damage analysis by the alkaline comet assay.

Mutat Res Genet Toxicol Environ Mutagen

EPIUnit-Instituto de Saúde Pública, Universidade do Porto, Porto, Portugal; Instituto Nacional de Saúde Dr. Ricardo Jorge, Departamento de Saúde Ambiental, Porto, Portugal. Electronic address:

Published: September 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The comet assay is a commonly used method for in vitro and in vivo genotoxicity assessment. This versatile assay can be performed in a wide range of tissues and cell types. Although most of the studies use samples immediately processed after collection, frozen biological samples can also be used. The present study aimed to optimize a collection and freezing protocol to minimize the DNA damage associated with these procedures in human cell line samples for comet assay analysis. This study was conducted in glial A172 and lung alveolar epithelial A549 cells. Two cell detachment methods (mechanical vs enzymatic) and two cryoprotective media [FBS + 10% DMSO vs Cell Culture Media (CCM) + 10% DMSO] were tested, and DNA damage assessed at four time points following storage at -80 °C (one, two, four and eight weeks). In both cell lines, no differences in % tail intensity were detected between fresh and frozen cells up to eight weeks, irrespective of the harvesting method and freezing medium used. However, freshly isolated A172 cells exhibited a significant lower DNA damage when resuspended in CCM + 10% DMSO, while for A549 fresh cells the preferable harvesting method was the enzymatic one since it induced less DNA damage. Although both harvesting methods and cryoprotective media tested were found suitable, our data indicate that enzymatic harvesting and cryopreservation in CCM + 10% DMSO is a preferable method for DNA integrity preservation of human cell line samples for comet assay analysis. Our data also suggest that CCM is a preferable and cost-effective alternative to FBS in cryopreservation media. This optimized protocol allows the analysis of in vitro cell samples collected and frozen at different locations, with minimal interference on the basal DNA strand break levels in samples kept frozen up to eight weeks.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mrgentox.2018.12.002DOI Listing

Publication Analysis

Top Keywords

dna damage
20
comet assay
16
human cell
12
cell samples
12
cell
8
cell lines
8
samples comet
8
assay analysis
8
cryoprotective media
8
harvesting method
8

Similar Publications