98%
921
2 minutes
20
The theoretical prediction of a display viewing angle control using a guest-host (GH) liquid crystal (LC) cell has been reported by Chen et al. [Jpn. J. Appl. Phys.48, 062401 (2009)JJAPA50021-492210.1143/JJAP.48.062401]. We experimentally confirmed the viewing angle control property of the GH cell and also investigated its dependence on the extinction coefficient of the GH mixture. The GH cell with a negative dielectric anisotropy and a vertical orientation was attached on front of the display panel, resulting in narrow viewing (NV) property at the field-off state. The GH molecules were switched to a planar orientation, which is also orthogonal to the polarization direction of light at the field-on state, showing wide viewing (WV) property. We varied the concentration of a guest dichroic dye in a host LC and measured the extinction coefficients of the mixtures. We simulated the viewing control property using the measured extinction coefficients and found that the horizontal viewing angle can be controlled using the GH cell, but the vertical viewing angle cannot be controlled. Then, we experimentally confirmed the horizontal viewing angle control using the GH cell. The extinction between the NV and the WV states was increased with a greater extinction coefficient of the GH molecules, but the transmittance was decreased.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.58.006105 | DOI Listing |
JB JS Open Access
September 2025
Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan.
Background: Lower extremity alignment in knee osteoarthritis (OA) is conventionally assessed using standing radiographs. However, symptoms often manifest during gait. Understanding dynamic alignment during gait may help characterize disease progression and inform treatment strategies.
View Article and Find Full Text PDFInt Biomech
December 2025
School of Medicine, Medical Sciences and Nutrition, University of Aberdeen, Aberdeen, UK.
This study evaluates the accuracy of single camera markerless motion capture (SCMoCap) using Microsoft's Azure Kinect, enhanced with inverse kinematics (IK) via OpenSim, for upper limb movement analysis. Twelve healthy adults performed ten upper-limb tasks, recorded simultaneously by OptiTrack (marker-based) and Azure Kinect (markerless) from frontal and sagittal views. Joint angles were calculated using two methods: (1) direct kinematics based on body coordinate frames and (2) inverse kinematics using OpenSim's IK tool with anatomical keypoints.
View Article and Find Full Text PDFArch Craniofac Surg
August 2025
Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Zagazig University, Zagazig, Egypt.
Background: The pre-lacrimal window (PLW) approach is a promising technique for accessing otherwise inaccessible maxillary sinus lesions. The objective of this study was to determine the computed tomography (CT) dimensions, measurements, and grading of the PLW.
Methods: One hundred paranasal CT scans were included in the study.
Quant Imaging Med Surg
September 2025
School of Computer and Information Technology, Shanxi University, Taiyuan, China.
Background: Electron paramagnetic resonance imaging (EPRI)-based oxygen imaging technology enables adaptive radiation therapy, thereby improving tumor control rates. However, the long scanning time limits the development of EPRI. In this study, we endeavored to reduce the scanning time.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
September 2025
Objective: coronary rotational atherectomy (CRA) is a vital method for the treatment of cardiovascular calcified blockages, but the lack of intravascular information may lead to improper setting of rotary parameters, posing risks of surgical complications. Forward-looking intravascular ultrasound (FL-IVUS) is a valuable tool for lumen imaging and has unique advantages in severely calcified or even occluded vessels.
Methods: in this study, a visual rotary surgical instrument based on FL-IVUS imaging was proposed to achieve intraoperative feedback.