A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Multiplexed Immunohistochemical Consecutive Staining on Single Slide (MICSSS): Multiplexed Chromogenic IHC Assay for High-Dimensional Tissue Analysis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Disease states and cellular compartments can display a remarkable amount of heterogeneity, and truly appreciating this heterogeneity requires the ability to detect and probe each subpopulation present. A myriad of recent single-cell assays has allowed for in-depth analysis of these diverse cellular populations; however, fully understanding the interplay between each cell type requires knowledge not only of their mere presence but also of their spatial organization and their relation one to the other. Immunohistochemistry allows for the visualization of cells and tissue; however, standard techniques only allow for the use of very few probes on a single specimen, not allowing for in-depth analysis of complex cellular heterogeneity. A number of multiplex imaging techniques, such as immunofluorescence and multiplex immunohistochemistry, have been proposed to allow probing more cellular markers at once; however, many of these techniques still have their limitations. The use of fluorescent markers has an inherent limitation to the number of probes that can be simultaneously used due to spectral overlap. Moreover, other proposed multiplex IHC methods are time-consuming and require expensive reagents. Still, many of the methods rely on frozen tissue, which deviates from standards in human pathological evaluation. Here, we describe a multiplex IHC technique, staining for consecutive markers on a single slide, which utilizes similar steps and similar reagents as standard IHC, thus making it possible for any lab with standard IHC capabilities to perform this useful procedure. This method has been validated and confirmed that consecutive markers can be stained without the risk of cross-reactivity between staining cycles. Furthermore, we have validated that this technique does not lead to decreased antigenicity of subsequent epitopes probed, nor does it lead to steric hindrance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869027PMC
http://dx.doi.org/10.1007/978-1-4939-9773-2_23DOI Listing

Publication Analysis

Top Keywords

single slide
8
in-depth analysis
8
multiplex ihc
8
consecutive markers
8
standard ihc
8
ihc
5
multiplexed immunohistochemical
4
immunohistochemical consecutive
4
consecutive staining
4
staining single
4

Similar Publications