A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Biphasic calcium phosphate with submicron surface topography in an model of instrumented posterolateral spinal fusion. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

As spinal fusions require large volumes of bone graft, different bone graft substitutes are being investigated as alternatives. A subclass of calcium phosphate materials with submicron surface topography has been shown to be a highly effective bone graft substitute. In this work, a commercially available biphasic calcium phosphate (BCP) with submicron surface topography (MagnetOs; Kuros Biosciences BV) was evaluated in an model of instrumented posterolateral fusion. The material was implanted stand-alone, either as granules (BCP) or as granules embedded within a fast-resorbing polymeric carrier (BCP) and compared to autograft bone (AG). Twenty-five adult, female Merino sheep underwent posterolateral fusion at L2-3 and L4-5 levels with instrumentation. After 6, 12, and 26 weeks, outcomes were evaluated by manual palpation, range of motion (ROM) testing, micro-computed tomography, histology and histomorphometry. Fusion assessment by manual palpation 12 weeks after implantation revealed 100% fusion rates in all treatment groups. The three treatment groups showed a significant decrease in lateral bending at the fusion levels at 12 weeks ( < 0.05) and 26 weeks ( < 0.001) compared to the 6 week time-point. Flexion-extension and axial rotation were also reduced over time, but statistical significance was only reached in flexion-extension for AG and BCP between the 6 and 26 week time-points ( < 0.05). No significant differences in ROM were observed between the treatment groups at any of the time-points investigated. Histological assessment at 12 weeks showed fusion rates of 75%, 92%, and 83% for AG, BCP and BCP, respectively. The fusion rates were further increased 26 weeks postimplantation. Similar trends of bone growth were observed by histomorphometry. The fusion mass consisted of at least 55% bone for all treatment groups 26 weeks after implantation. These results suggest that this BCP with submicron surface topography, in granules or putty form, is a promising alternative to autograft for spinal fusion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6686792PMC
http://dx.doi.org/10.1002/jsp2.1039DOI Listing

Publication Analysis

Top Keywords

calcium phosphate
12
submicron surface
12
surface topography
12
bone graft
12
biphasic calcium
8
model instrumented
8
instrumented posterolateral
8
posterolateral fusion
8
manual palpation
8
treatment groups
8