A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Ultrasensitive immunoassay for detection of Citrus tristeza virus in citrus sample using disposable microfluidic electrochemical device. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Tristeza is a disease that affects citrus crops in general, caused by the Citrus tristeza virus (CTV). It is considered an economically important virus diseases in citrus, which is present in the main citrus producing regions all around the world. Early detection of CTV is crucial to avoid any epidemics and substantial economic losses for the citrus growers. Consequently, the development of rapid, accurate, and sensitive methods capable of detecting the virus in the early stages of the disease is highly desired. Based on that, a low-cost and rapid magneto-immunoassay methodology to detect the capsid protein from CTV (CP-CTV) was proposed. For this, magnetic beads were decorated with antibodies anti-CP-CTV and horseradish peroxidase enzyme (HRP) and applied for the capture and separation of CP-CTV from the sample solutions. The magnetically captured biomarker was detected using a simple disposable microfluidic electrochemical device (DμFED) constructed by rapid prototyping technique and composed by an array of immunosensors. In DμFED, the electrodes were modified with monoclonal antibody anti-CP-CTV and the detection was carried out using amperometry, based on the hydroquinone/HO catalytic redox reaction due to the presence of HRP label in an immune-sandwich structure. The proposed immunoassay presented excellent linearity with a wide linear range of concentration of 1.95-10.0 × 10 fg mL and ultralow detection limit of 0.3 fg mL. The disposable device was successfully applied for the detection of Citrus tristeza virus in healthy and infected plant samples, where it showed good agreements with the comparative method of enzyme-linked immunosorbent assay (ELISA). The developed immunoassay methodology showed a sensitive and selective way in the detection of CTV. Hence, it can be considered as a promising analytical alternative for rapid and low-cost diagnosis of Tristeza disease in citrus.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2019.07.005DOI Listing

Publication Analysis

Top Keywords

citrus tristeza
12
tristeza virus
12
citrus
9
detection citrus
8
disposable microfluidic
8
microfluidic electrochemical
8
electrochemical device
8
tristeza disease
8
disease citrus
8
ctv considered
8

Similar Publications