A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Intersubject and Intrasubject Variability of Potential Plasma and Urine Metabolite and Protein Biomarkers in Healthy Human Volunteers. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A limited understanding of intersubject and intrasubject variability hampers effective biomarker translation from in vitro/in vivo studies to clinical trials and clinical decision support. Specifically, variability of biomolecule concentration can play an important role in interpretation, power analysis, and sampling time designation. In the present study, a wide range of 749 plasma metabolites, 62 urine biogenic amines, and 1,263 plasma proteins were analyzed in 10 healthy male volunteers measured repeatedly during 12 hours under tightly controlled conditions. Three variability components in relative concentration data are determined using linear mixed models: between (intersubject), time (intrasubject), and noise (intrasubject). Biomolecules such as 3-carboxy-4-methyl-5-propyl-2-furanpropanoate, platelet-derived growth factor C, and cathepsin D with low noise potentially detect changing conditions within a person. If also the between component is low, biomolecules can easier differentiate conditions between persons, for example cathepsin D, CD27 antigen, and prolylglycine. Variability over time does not necessarily inhibit translatability, but requires choosing sampling times carefully.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cpt.1606DOI Listing

Publication Analysis

Top Keywords

intersubject intrasubject
8
intrasubject variability
8
variability
5
variability potential
4
potential plasma
4
plasma urine
4
urine metabolite
4
metabolite protein
4
protein biomarkers
4
biomarkers healthy
4

Similar Publications