Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Introduction: Artefacts caused by dental implants and hip replacements may impede target volume definition and dose calculation accuracy. The iterative metal artefact reduction (iMAR) algorithm can provide a solution for this problem. The present study compares delineation of gross tumour volumes (GTVs) and organs at risk (OARs) in the pelvic and the head and neck (H & N) regions using computed tomography (CT) with and without iMAR, and thus the practical applicability of iMAR for routine clinical use.
Methods: The native planning CT and CT-iMAR data of two typical clinical cases with image-distorting artefacts were used for multi-institutional contouring and analysis using the Dice similarity coefficient (DSC). GTV/OAR contours were compared with an intraobserver approach and compared to predefined reference structures.
Results: Mean volume for GTV in the intraobserver approach decreased from 87 ± 44 cm (native CT) to 75 ± 22 cm (CT-iMAR) (P = 0.168). Compared to the reference, DSC values for GTV increased from 0.68 ± 0.15 to 0.78 ± 0.07 (CT vs. iMAR) (P < 0.05). In the H & N region, the reference for GTV (34 cm ) was underestimated on both data sets. No significant improvement in DSC values (0.83 ± 0.06 (native CT) versus 0.86 ± 0.06 (CT-iMAR)) was observed.
Conclusion: The use of iMAR improves the anatomical delineation at the transition of prostate and bladder in cases of bilateral hip replacement. In the H & N region, anatomical residual structures and experience were apparently sufficient for precise contouring.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/1754-9485.12924 | DOI Listing |