A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Internal Biomechanical Study of a 70-Year-Old Female Human Lumbar Bi-Segment Finite Element Model and Comparison with a Middle-Aged Male Model. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The main purpose of this article is to study the biomechanics of spine tissue in elderly female. In this study, the L3-L5 lumbar bi-segmental finite element model for elderly female was obtained from the Advanced Human Modeling Laboratory of the Bioengineering Center at Wayne State University. The effects of flexion and extension on bone geometry, distribution of ligament fibers, location of nucleus, and changes in intervertebral disc height were studied by comparing the results obtained before and after the update of older female and middle-aged male models. For the purpose of comparing the calculated range of motion (ROM) with the experimental data, additional calculations for axial rotation and lateral bending were performed. The study found that the parameters of the model affected the deformation of the disc herniation, ligament and intervertebral disc, and the axial force carrying capacity of the model. The three predicted ROMs are usually similar to the experimental results. Only the older female model has a slightly larger ROM. Therefore, older women are more vulnerable to lumbar spine injuries than men.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6515178PMC
http://dx.doi.org/10.1155/2019/9794365DOI Listing

Publication Analysis

Top Keywords

finite element
8
element model
8
middle-aged male
8
elderly female
8
intervertebral disc
8
older female
8
model
6
female
5
internal biomechanical
4
study
4

Similar Publications