Purpose: To systematically analyze intravoxel incoherent motion (IVIM) MRI in a perfusable capillary phantom closely matching the geometry of capillary beds in vivo and to compare the validity of the biexponential pseudo-diffusion and the recently introduced phase-distribution IVIM model.
Methods: IVIM-MRI was performed at 12 different flow rates ( ) in a capillary phantom using 4 different DW-MRI sequences (2 with monopolar and 2 with flow-compensated diffusion-gradient schemes, with up to values between and ). Resulting parameters from the assessed IVIM models were compared to results from optical microscopy.
Results: The acquired data were best described by a static and a flowing compartment modeled by the phase-distribution approach. The estimated signal fraction of the flowing compartment stayed approximately constant over the applied flow rates, with an average of in excellent agreement with optical microscopy ( ). The estimated average particle flow speeds showed a highly significant linear correlation to the applied flow. The estimated capillary segment length of approximately agreed well with optical microscopy measurements. Using the biexponential model, the signal fraction was substantially underestimated and displayed a strong dependence on the applied flow rate.
Conclusion: The constructed phantom facilitated the detailed investigation of IVIM-MRI methods. The results demonstrate that the phase-distribution method is capable of accurately characterizing fluid flow inside a capillary network. Parameters estimated using the biexponential model, specifically the perfusion fraction , showed a substantial bias because the model assumptions were not met by the underlying flow pattern.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6771596 | PMC |
http://dx.doi.org/10.1002/mrm.27816 | DOI Listing |
Int J Health Care Qual Assur
September 2025
Department of Electrical and Computer Engineering, Graduate University of Advanced Technology, Kerman, Iran.
Purpose: Neonatal mortality is a significant global health issue, particularly in low- and middle-income countries. This study aims to identify and understand the factors contributing to high neonatal mortality rates in the cities of Kerman and Bam, Iran, to develop effective strategies for improvement.
Design/methodology/approach: We employed systems dynamics to develop Causal Loop Diagrams that capture qualitative interactions among determinants of neonatal mortality.
ESC Heart Fail
September 2025
Department of Cardiac-, Thoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
Aims: Non-pharmacological therapies for acute decompensated heart failure (HF) and cardiogenic shock have evolved considerably in recent decades. Short-term mechanical circulatory support (MCS) devices can be used as circulatory backup. While nearly all available devices use continuous flow, evidence indicates that pulsatile flow can be more effective.
View Article and Find Full Text PDFRapid Commun Mass Spectrom
September 2025
Département Médicaments et Technologies pour la Santé (DMTS), MetaboHUB, Université Paris-Saclay, CEA, INRAE, Gif sur Yvette, France.
Rationale: Electrospray (ESI), the most popular desorption/ionization technique used in mass spectrometry-based metabolomics, generates both protonated and deprotonated molecules, as well as adduct ions, sodium being the most frequent monoatomic cation entering their composition. With the spread and generalization of untargeted data-dependent and independent tandem mass spectrometry experiments, considering product ion spectra of sodium-containing entities appears relevant to complement fragmentation information of their protonated and deprotonated counterparts.
Methods: Solutions of pure standards, mainly amino and organic acids, were prepared at 1 μg/mL and injected either by direct infusion or by flow-injection prior to ESI-MS/MS analysis.
Appl Nurs Res
October 2025
Faculty of Nursing, Yarmouk University, Irbid, Jordan. Electronic address:
Background: Effective communication between ICU nurses and patients' families is essential in ensuring optimal care, reducing anxiety, and enhancing decision-making. However, communication difficulties persist globally, particularly in intensive care units (ICUs) where patients are in critical condition and their families are distressed. Aim To explore the lived experiences of ICU nurses and family members in Jordan to understand how nurse workload, emotional stress, and cultural expectations influence the quality, clarity, and emotional tone of communication in intensive care settings.
View Article and Find Full Text PDFChest
September 2025
Flinders Health and Medical Research Institute/Adelaide Institute for Sleep Health, Flinders University, Bedford Park, South Australia, Australia.
Background: Hypoglossal nerve stimulation (HNS) to treat obstructive sleep apnea (OSA) currently requires placement of a cuff or 'saddle' electrode around or adjacent to the hypoglossal nerve(s). Limitations for this therapy include cost, invasiveness, and variable efficacy.
Research Question: Can HNS applied via percutaneous implantation of a linear, multi-pair electrode array restore airflow to airway narrowing and/or obstruction, and improve airway collapsibility in people with OSA?
Study Design And Methods: Participants with OSA undergoing drug induced sleep endoscopy with propofol were instrumented with an epiglottic pressure catheter, nasal mask and pneumotachograph.