A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

FaPEx® Multipesticide Residues Extraction Kit for Minimizing Sample Preparation Time in Agricultural Produce. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The quick, easy, cheap, effective, rugged, and safe method, generally applied to the determination of pesticide residues in food, has been recently modified and adopted for the analysis of pesticide residues worldwide, including Taiwan. The method still needs to be improved, particularly in efficiency and normalization, because the time costs 20-30 min for extraction and cleanup of multiple pesticides in every food. In this study, we present a highly efficient and simple sample preparation method that was developed for the determination of 380 pesticide residues in food, including mangoes, scallions, bok choy, apples, carrots, and pea seedlings. The homogenized 1 g samples mixed with 5 mL 1.0% acetic acid in acetonitrile were pushed through the FaPEx® (fast pesticide extraction) kits in a dropwise manner to obtain sample extracts. The total processing time was less than 15 min. The extracts were subject to chromatographic separation followed by GC-tandem MS (MS/MS) and LC-MS/MS analysis. For more than 270 pesticide residues in these foods, the test gave acceptable mean recoveries, ranging between 70 and 120%, and relative SDs below 20%. The LOQ was at least 0.01 mg/kg for 380 pesticides. The developed method can greatly reduce the time needed for multiple pesticide residues analysis. FaPEx is used for the extraction of pesticide residues that relies on single-use pre-filled sealed cartridges. FaPEx diminishes operation time, glassware demand, and laboratory space requirement. It also significantly decreases the amount of chemical solvents.

Download full-text PDF

Source
http://dx.doi.org/10.5740/jaoacint.18-0271DOI Listing

Publication Analysis

Top Keywords

pesticide residues
24
sample preparation
8
residues food
8
residues
7
pesticide
7
time
5
fapex® multipesticide
4
multipesticide residues
4
extraction
4
residues extraction
4

Similar Publications