A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Polymerization Shrinkage Evaluation of Restorative Resin-Based Composites Using Fiber Bragg Grating Sensors. | LitMetric

Polymerization Shrinkage Evaluation of Restorative Resin-Based Composites Using Fiber Bragg Grating Sensors.

Polymers (Basel)

Institute of Operative Dentistry, Dentistry Area, Faculty of Medicine, University of Coimbra, Avenida Bissaya Barreto, Blocos de Celas, 3700-075 Coimbra, Portugal.

Published: May 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The purpose of this study was to compare the linear polymerization shrinkage of different restorative resin-based composites (RBCs) using fiber Bragg grating (FBG) sensors. Five RBCs were evaluated: Zirconfill (ZFL); Aura Bulk-Fill (ABF); Tetric N-Ceram Bulk-Fill (TBF); Filtek Bulk-Fill (FBF); and Admira Fusion-Ormocer (ADF). Ten samples per resin were produced in standardized custom-made half-gutter silicone molds. Two optical FBG sensors were used to assess temperature and polymerization shrinkage. Light curing was performed for 40 s and polymerization shrinkage was evaluated at 5, 10, 40, 60, 150, and 300 s. Statistical analysis was accomplished for normal distribution (Shapiro-Wilk, > 0.05). Two-way repeated measures ANOVA with Greenhouse-Geisser correction followed by Bonferroni's post-hoc test was used to analyze the linear shrinkage data ( < 0.05). ZFL showed the highest linear shrinkage and ADF the lowest. Shrinkage increased for all RBCs until 300 s, where significant differences were found between ADF and all other resins ( < 0.05). Among bulk-fill RBCs, TBF showed the lowest shrinkage value, but not statistically different from FBF. The ADF presented lower linear shrinkage than all other RBCs, and restorative bulk-fill composites exhibited an intermediate behavior.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6571745PMC
http://dx.doi.org/10.3390/polym11050859DOI Listing

Publication Analysis

Top Keywords

polymerization shrinkage
16
linear shrinkage
12
restorative resin-based
8
resin-based composites
8
fiber bragg
8
bragg grating
8
shrinkage
8
fbg sensors
8
lowest shrinkage
8
rbcs
5

Similar Publications