A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Low-Cost Haptic Simulation Using Material Fracture. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Medical simulation training is widely used to effectively train for invasive medical procedures such as peripheral nerve blocks. Traditionally, accurate haptic training relies on expensive cadavers, manikins, or advanced haptic robots. Proposed herein is a novel concept for haptic training called the low-cost haptic force needle insertion simulator (LCNIS), which uses material fracture inside disposable cartridges to accurately replicate the force of inserting a needle into tissue. Cadaver and material fracture experiments were performed to develop and determine the accuracy of the LCNIS. The material testing showed that polycarbonate had the highest maximum needle puncture force of the materials tested, 9.85 N, and that fluorinated ethylene propylene had the lowest maximum puncture force, 0.84 N. The cadaver results showed that the error between the three peak forces in a cadaver and a cadaver mimicking cartridge was 1.00 N, 0.01 N, and 1.54 N. The standard deviation of these peaks was 0.60 N, 0.55 N, and 0.41 N. This novel method of haptic simulation can easily be adapted to recreate any type of force and, therefore, could be utilized to train for a wide variety of medical procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6944059PMC
http://dx.doi.org/10.1109/TOH.2019.2914441DOI Listing

Publication Analysis

Top Keywords

material fracture
12
low-cost haptic
8
haptic simulation
8
medical procedures
8
haptic training
8
lcnis material
8
puncture force
8
haptic
5
force
5
material
4

Similar Publications