A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A quadruple-channel fluorescent sensor array based on label-free carbon dots for sensitive detection of tetracyclines. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A quadruple-channel fluorescent sensor array based on label-free carbon dots (CDs) was fabricated to detect and discriminate a series of tetracyclines (TCs), including chlortetracycline (CTC), oxytetracycline (OTC), tetracycline (TC) and doxycycline (DOX). Blue-emitting carbon dots (B-CDs) and green-emitting carbon dots (G-CDs) were prepared to serve as four sensing elements. When the TCs were directly mixed with CDs, the fluorescence quenching phenomenon appeared. Since different TCs exhibited different affinities for sensing elements, the sensor array displays a distinct fluorescence pattern of the fluorescence intensity variation (F0 - F)/F0 for each of these TCs, which is further analyzed by principal component analysis (PCA). The present fluorescent sensor array has the capacity to differentiate TCs at a low concentration of 1 μM. Meanwhile, quantitative detection with a lower limit (0.30 μM) for TCs could be achieved by applying a single element. Moreover, a high accuracy (100%) examination of unknown samples is acquired. Finally, the fluorescent sensor array performs well in distinguishing binary mixtures and could also recognize TCs in milk.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c9an00148dDOI Listing

Publication Analysis

Top Keywords

sensor array
20
fluorescent sensor
16
carbon dots
16
quadruple-channel fluorescent
8
array based
8
based label-free
8
label-free carbon
8
sensing elements
8
tcs
7
sensor
5

Similar Publications