Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
This study reports on the results of gaseous pollutants emission measurements of double-decker buses in an urban road network, using portable emission measurement systems (PEMS). Measured vehicles were tested by following in-service buses on regular routes. Six Euro II and Euro III buses were retrofitted with diesel particulate filters (DPF) and selective catalytic reduction (SCR) or a combined SCR+DPF (SCRT) device. Substantial and statistically significant technology impacts were observed for several pollutants. Optimized SCR and SCRT retrofit technology reduced real-world NO emissions by approximately 70%, on average. Retrofit DPF slightly reduced NO emissions but increased direct NO emissions by more than a factor of 8, on average. SCRT led to about 70% lower NO levels than DPF alone, but for some vehicles higher NO levels were observed as compared with the "no retrofit" situation, warranting further investigation. None of the SCR systems were found to lead to a substantial increase in NH emissions after operation optimization. High NH and NO emissions were occasionally observed while experience with the system calibration was being accumulated. Observed average NO emission levels for "DPF+SCR" technology were relatively high at 182 mg/kg fuel, corresponding to 1.5% of total greenhouse gas emissions. The study shows that SCR retrofit programs can be effective for NO reduction of transit buses but that proper calibration and regular emission monitoring are required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.est.8b07223 | DOI Listing |