A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Improved Current Sensor for Water Diffusion Testing of Composite Insulators. | LitMetric

Improved Current Sensor for Water Diffusion Testing of Composite Insulators.

Sensors (Basel)

Department of Electrical Engineering, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.

Published: February 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

An improved current sensor aimed at measuring currents of different parts in composite insulator samples was proposed. Conventional current sensors used in water diffusion tests aim to examine the performance of composite insulators, however, it is difficult for the conventional current sensors to locate the defects. Thus, we designed a new electrode structure to measure the currents of different components in short samples of composite insulators. Based on a finite analysis method, the influence of relative permittivity and conductivity on the current was analyzed. New samples with different interfaces and samples after operation were tested using the new and conventional current sensors. The performance of a certain part in short samples can be diagnosed by analyzing the current and phase information extracted from the test results. By comparing the test results of new and traditional current sensors, it was proved that the new electrode structure is more effective in locating the defects of insulators.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412980PMC
http://dx.doi.org/10.3390/s19040778DOI Listing

Publication Analysis

Top Keywords

current sensors
16
composite insulators
12
conventional current
12
improved current
8
current sensor
8
water diffusion
8
electrode structure
8
short samples
8
current
7
samples
5