A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Bubble Dislodgment in a Capillary Network with Microscopic Multichannels and Multibifurcation Features. | LitMetric

Bubble Dislodgment in a Capillary Network with Microscopic Multichannels and Multibifurcation Features.

Langmuir

Institute for Materials and Processes, School of Engineering , The University of Edinburgh, The King's Buildings, Robert Stevenson Road , Edinburgh EH9 3FB , U.K.

Published: February 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Bubble lodgment in a complex capillary network is a common issue in many industrial and biological processes. Research work reported in the literature only investigated bubble dislodgment in single channels and did not consider the effect of network complexity on the dislodgment. This paper focuses on the pressure required to dislodge single bubbles from a microscopic capillary network and investigates the factors affecting the dislodging pressure to facilitate the precise control of bubble flows in porous media. A capillary network with multibifurcation and a smoothly changed diameter is designed to closely mimic the structure of the physiological vascular networks. Over 600 bubble dislodgment experiments have been conducted to understand the effect of the network structure, channel dimensions, and bubble length on the dislodging pressure. The results indicate that the network structure is a dominant factor affecting the dislodging pressure that increases with the increase in network complexity. The effect of bubble length on the dislodging pressure depends on the bubble length. When the bubble length is less than a certain value, which is around 2 mm in this study, the dislodging pressure increases significantly with the decrease of bubble length. When the bubble length is larger than 2 mm, the dislodging pressure is independent of the bubble length. A model has been proposed to explain the bubble dislodgment in complex capillary networks. The impact of the network structure on the bubble dislodging pressure is characterized by a parameter c . The model indicates that the dislodging pressure is the function of bubble length, channel dimension, and network structure. The analysis of model parameters NB and MA shows that parameter c , rather than the channel size, dominates the dislodging pressure for bubbles with a length greater than 2 mm, and the increase rate of the dislodging pressure is significantly affected by both channel size and parameter c .

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.langmuir.8b03323DOI Listing

Publication Analysis

Top Keywords

dislodging pressure
40
bubble length
32
bubble dislodgment
16
capillary network
16
network structure
16
bubble
15
pressure
11
network
10
dislodging
10
length
9

Similar Publications