Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Although delayed umbilical cord clamping has been shown to have significant benefits for both term and preterm infants, currently, data on its impact on blood gas analysis have been scant and conflicting.
Methods: In a retrospective review, we compared the demographic characteristics and blood gas parameters of 114 delayed cord clamping (DCC-births between 45 and 90 s in length; 109 being for 60 s) versus 407 early cord clamping births (ECC-immediately after delivery) collected over a 1-year period. Intrapartum care and timing of cord clamping for individual cases were performed at the discretion of obstetricians. The differences were assessed for statistical and clinical significance.
Results: The DCC group was found to have significantly higher mean Apgar scores at both 1 and 5 min (p < 0.05), as well as lower percentages of nulliparous births, cesarean-section deliveries, epidural anesthesia usage, and major pregnancy-related complications. No significant differences in maternal age, gestational age, neonate birthweight, sex, or in the presence of meconium at birth were observed. A higher umbilical artery pO in the DCC group [21 (9) vs. 19 (10) mmHg, p < 0.05] was the only statistically significant difference found out of all the blood gas parameters analyzed.
Conclusions: In this study, infants selected for the DCC procedure were found to be overall lower risk than those delivered as per the standard ECC procedure. No clinically significant difference in any blood gas parameter was observed, and therefore, no adjustment to clinical reference intervals is needed for DCC blood gas samples taken after a 1-min delay period.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00404-019-05048-5 | DOI Listing |