Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Cryolipolysis is the noninvasive treatment of localized fat through cold-induced panniculitis. The purpose of the present study was to evaluate the safety and efficacy of contrast cryolipolysis for subcutaneous-fat reduction. Contrast cryolipolysis mixes the principles of conventional cryolipolysis and periods of heating in accordance with the contrast lipocryolysis process. Twenty-one subjects aged 34 ± 9 years were treated with contrast cryolipolysis in the regions of abdomen and flanks through the Polarys® device. Anthropometry, standardized photographs, measurements with a skinfold caliper, and diagnostic ultrasounds were performed at the baseline and during follow-ups at 30, 60, and 90 days after the treatment. The safety assessments included laboratory testing and monitoring of the adverse events. The level of significance for all tests was set at < 0.05. No significant differences in weight and body mass index were found. The waist measurements at the baseline and 30-day follow-up had significant differences, as did the measurements at the 30-day and 60-day follow-ups. The skinfold and ultrasound measurements were significantly reduced in the treated areas in all the time points compared to the baseline. The laboratory results showed no significant changes from baseline. Temporary adverse effects were resolved spontaneously. This study confirmed that contrast cryolipolysis is safe and effective in reducing the fat layer and improving body contouring.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6304526 | PMC |
http://dx.doi.org/10.1155/2018/5276528 | DOI Listing |