98%
921
2 minutes
20
Objective: The objective of this study was to investigate the impact of left atrial (LA) size for the ablation of atrial fibrillation (AF) using remote magnetic navigation (RMN).
Methods: A total of 165 patients with AF who underwent catheter ablation using RMN were included. The patients were divided into two groups based on LA diameter. Eighty-three patients had small LA (diameter <40 mm; Group A), and 82 patients had a large LA (diameter ≥40 mm; Group B).
Results: During mapping and ablation, X-ray time (37.0 (99.0) s vs. 12 (30.1) s, < 0.001) and X-ray dose (1.4 (2.7) gy·cm vs. 0.7 (2.1) gy·cm, =0.013) were significantly higher in Group A. No serious complications occurred in any of the patients. There was no statistical difference in the rate of first anatomical attempt of pulmonary vein isolation between the two groups (71.1% vs. 57.3%, =0.065). However, compared with Group B, the rate of sinus rhythm was higher (77.1% vs. 58.5%, < 0.001) during the follow-up period. More patients in Group A required a sheath adjustment (47/83 vs. 21/82, < 0.001), presumably due to less magnets positioned outside of the sheath. experiments with the RMN catheter demonstrated that only one magnet exposed created the sheath affects which influenced the flexibility of the catheter.
Conclusions: AF ablation using RMN is safe and effective in both small and large LA patients. Patients with small LA may pose a greater difficulty when using RMN which may be attributed to the fewer magnets beyond the sheath. As a result, the exposure of radiation was increased. This study found that having at least two magnets of the catheter positioned outside of the sheath can ensure an appropriate flexibility of the catheter.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6304809 | PMC |
http://dx.doi.org/10.1155/2018/3096261 | DOI Listing |
J Prosthet Dent
September 2025
Full Professor, School of Mechanical Engineering, Universidad Industrial de Santander, Bucaramanga, Colombia. Electronic address:
Statement Of Problem: Although custom temporomandibular joint (TMJ) prostheses manufactured via computer-aided design and manufacturing (CAD-CAM) and produced through 3-dimensional (3D) printing or computer numerical control (CNC) allow for sagittal curvature adjustments in the glenoid fossa, their design remains unregulated by the Food and Drug Administration. Consequently, the geometry is determined largely by the engineer's discretion, with limited biomechanical evidence to guide these decisions. The lack of validation regarding how sagittal curvature influences joint stress distribution under various anatomical and functional conditions represents a gap in current knowledge that warrants investigation.
View Article and Find Full Text PDFJ Am Coll Cardiol
September 2025
Service de Médecine Intensive-Réanimation, Institut de Cardiologie, Assistance Publique-Hôpitaux de Paris (AP-HP), Sorbonne Université, Hôpital Pitié-Salpêtrière, Paris, France; Sorbonne Université, INSERM, UMRS_1166-ICAN, Institute of Cardiometabolism and Nutrition, Paris, France.
Background: The hemodynamic effects of femoro-femoral venoarterial (VA) extracorporeal membrane oxygenation (ECMO) on pulmonary capillary wedge pressure (PCWP) remain poorly defined. High ECMO flow is believed to increase PCWP and the risk of pulmonary edema; yet, supporting in vivo physiological data are lacking.
Objectives: The purpose of this study was to evaluate the impact of incremental femoro-femoral VA-ECMO flow variations on PCWP, hemodynamic, and echocardiographic parameters in patients with cardiogenic shock during the early phase of VA-ECMO support, after stabilization.
Prog Cardiovasc Dis
September 2025
Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA. Electronic address:
Objectives: This study explores the impact of lower baseline aortic valve (AV) mean gradients on the clinical outcomes of patients with low-gradient aortic stenosis (LG AS) post-transcatheter aortic valve replacement (TAVR). Additionally, the study aims to understand the predictors of a lower baseline AV mean gradient (MG).
Background: Reduced left ventricular ejection fraction (LVEF) and low-flow states are known to correlate with worse clinical outcomes.
J Physiol
September 2025
Department of Cell and Molecular Biology, University of Hawaii, Honolulu, HI, USA.
Diagnoses of prediabetes and metabolic syndromes, such as metabolic-associated steatotic liver disease (MASLD), are increasing at an alarming rate worldwide, often simultaneously. A significant consequence of these is high risk of cardiovascular disease, highlighting the need for cardiac-specific therapeutics for intervention during the prediabetic stage. Recent studies have demonstrated that chemogenetic activation of the cardiac parasympathetic system through hypothalamic oxytocin (OXT) neurons provides cardioprotective effects in heart disease models by targeting excitatory neurotransmission to brainstem cardiac vagal neurons.
View Article and Find Full Text PDFInterdiscip Cardiovasc Thorac Surg
September 2025
Department of Electrophysiology, Abbott Inc, Chicago, IL.
We report the first use of the EnSite X system for intraoperative electrophysiological mapping during a robotic hybrid ablation (ROK-AF procedure) for long-standing persistent atrial fibrillation. Epicardial ablation targets were identified, and post-ablation electrical silencing was validated. Unlike conventional systems, its orientation-independent omnipolar technology provides directional activation vectors, high-resolution electrograms, and peak frequency analysis, thereby enhancing substrate characterisation.
View Article and Find Full Text PDF