A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Composite nanofibrous membranes of PLGA/Aloe vera containing lipid nanoparticles for wound dressing applications. | LitMetric

Composite nanofibrous membranes of PLGA/Aloe vera containing lipid nanoparticles for wound dressing applications.

Int J Pharm

NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Spain; Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain. Electronic address:

Published: February 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Electrospun nanofibrous dressings present suitable characteristics to be used in wound healing, such as high porosity and high surface area-to-volume ratio. In this study, a wound dressing based on PLGA and Aloe vera containing lipid nanoparticles (NLCs) was developed. NLCs were added in order to add a lipid component that could avoid the adhesion of the dressing to the wound and improve its handling. Membranes with and without NLCs were composed of uniform fibers of about 1 µm in diameter. Their porosity was above 80% and their thickness was about 160 µm. Both dressings showed similar water vapour transmission rate 1100 g/mday. The formulation containing NLCs presented a higher ultimate tensile strength (2.61 ± 0.46 MPa) and a higher water uptake. Both formulations were biocompatible in vitro. Furthermore, the cell adhesion assay demonstrated that both membranes had a low adherence profile, although it was lower with the dressing containing NLCs. Finally, their efficacy was evaluated in a full thickness wound healing assay conducted in db/db mice, where both enhanced healing similarly. Accordingly, the PLGA-AV-NLC membrane might be a promising strategy for the treatment of chronic wounds, since it improved handling in comparison to the formulation without NLCs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2018.12.010DOI Listing

Publication Analysis

Top Keywords

vera lipid
8
lipid nanoparticles
8
wound dressing
8
wound healing
8
formulation nlcs
8
nlcs
6
wound
5
composite nanofibrous
4
nanofibrous membranes
4
membranes plga/aloe
4

Similar Publications