98%
921
2 minutes
20
Background The measurement of hemoglobin A1c (HbA1c) is important for diagnosing diabetes mellitus as well as assessing glycemic control in diabetic patients. Commutable whole blood certified reference materials (CRMs) are needed in the measurement of HbA1c for method validation and/or as quality controls. Methods We developed three levels of hemolyzed whole blood CRMs for HbA1c. The certified values were determined using liquid chromatography-isotope dilution tandem mass spectrometry method (LC-IDMS/MS) where two "signature" hexapeptides of HbA1c and hemoglobin A0 (HbA0) were used as the calibration standards. The concentrations of the hexapeptide solutions were determined by amino acid analysis by the LC-IDMS/MS method using amino acid CRMs as the calibration standards. The commutability study was conducted by measuring 25 patient specimens and the whole blood CRMs by both LC-IDMS/MS method and various routine methods using six different clinical analyzers. Results The certified values were determined to be 35.1±2.0, 50.3±1.9 and 65.8±2.6 mmol/mol, respectively. These CRMs showed good commutability on five of the six clinical analyzers but showed poor commutability on one of the clinical analyzers that used similar method as two other analyzers where good commutability was observed. Conclusions With certified target values based on metrological traceability and good commutability on most of the clinical analyzers, the developed whole blood CRMs can be used for method validation or as quality control materials in the measurement of HbA1c. The commutability study results also underscored the need of commutability testing of clinical CRMs using various clinical analyzers.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/cclm-2018-0861 | DOI Listing |
J Glaucoma
September 2025
Department of Ophthalmology, Kurashiki Medical Center, Kurashiki, Okayama, Japan.
Prcis: Protocol 30-2 of Melbourne Rapid Fields, online computer perimetry, provides a portable, reliable, and patient-friendly alternative to Humphrey Field Analyzer 30-2 SITA fast protocol for Japanese all severity stages of glaucoma patients.
Purpose: Melbourne Rapid Fields (MRF) online computer perimetry is a web-browser-based software that offers white-on-white threshold perimetry using any computer. This study evaluates the perimetric results of 30-2 protocol from MRF performed using a laptop computer in comparison to Humphrey Field Analyzer (HFA).
Background: Malaria is one of the most infectious diseases, and electrolyte imbalance and mineral disturbances are common clinical manifestations. This study aimed to explore the effect of malaria on biochemical parameters in Sudanese patients with severe falciparum malaria.
Methods: A case-control study was conducted in the clinical laboratory of the Kosti Teaching Hospital between August 2022 and January 2023.
J Appl Lab Med
September 2025
Department of Pathology, UC San Diego Health, San Diego, CA, United States.
Background: While clinical laboratories routinely perform automated chemistry assays on approved specimens (e.g., plasma and serum), the FDA has not evaluated the validity of these assays for nonapproved specimens (e.
View Article and Find Full Text PDFVestn Oftalmol
September 2025
Krasnov Research Institute of Eye Diseases, Moscow, Russia.
Primary open-angle glaucoma (POAG) is characterized by chronic progressive damage to the retinal ganglion cell layer (GCL) and their axons, leading to gradual visual function loss. Currently, the gold standards for structural and functional assessment of the retina in glaucoma are static automated perimetry (SAP) and optical coherence tomography (OCT). However, in clinical practice, data from SAP and OCT may be insufficient to reliably determine the stage of glaucomatous optic neuropathy, monitor its progression, or differentiate it from other causes of visual dysfunction.
View Article and Find Full Text PDFDigit Health
September 2025
Information Technology Department, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China.
Objective: To evaluate the impact of integrating digital shadow technology with Lean Six Sigma methodology on intra-laboratory turnaround time (TAT) in a high-volume clinical laboratory, and to demonstrate how digital shadow architectures can enhance process visibility and drive sustainable operational improvements.
Methods: A retrospective, two-phase study was conducted in a tertiary cancer hospital from January to December 2024. Digital shadow technology was implemented by leveraging real-time, time-stamped data from the laboratory information system (LIS) to map specimen workflow milestones.