A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

[ARMS-PCR combined with capillary electrophoresis can be a sensitive and quantitative method for detection of MYD88-L265P mutation in lymphoma]. | LitMetric

[ARMS-PCR combined with capillary electrophoresis can be a sensitive and quantitative method for detection of MYD88-L265P mutation in lymphoma].

Zhongguo Shi Yan Xue Ye Xue Za Zhi

The First Affiliated Hospital of Soochow University, Suzhou 215006,China;Jiangsu Institute of Hematology, Key Laboratory of Thrombosis and Hemostasis of Ministry of Health, Collaborative Innovation Center of Hematology, Suzhou 215006,

Published: December 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To investigate the feasibility of sensitive and quantitative detection of MYD88 gene L265P mutation in lymphoma patients by using ARMS-PCR combined with capillary electrophoresis.

Methods: ARMS-PCR amplified MYD88 gene was analyzed by capillary electrophoresis in ABI 3730 sequencer; Exon 5 of the same gene was sequenced bi-directionally as reported.

Results: The sensitivity of detection L265P mutations by the ARMS-PCR combined with capillary electrophoresis and direct sequencing was 0.2% and 5%, respectively, according to the detection of the gradient-diluted plasmid standards. The detection rate of 184 patients was 13.59% and 8.28%, respectively (p<0.001). Moreover, the former method can successfully detect the mutation ratio(R=0.979), and the repeatabilities (CV=2.86%, 1.94%, 5.49%) are acceptable.

Conclusion: ARMS-PCR combined with capillary electrophoresis can quantitatively detect the MYD88 gene L265P mutation, and the detection sensitivity is significantly higher than sanger sequencing. As a supplement to the latter, it can effectively lead to the earlier diagnose and monitoring of minimal residual disease.

Download full-text PDF

Source
http://dx.doi.org/10.7534/j.issn.1009-2137.2018.06.014DOI Listing

Publication Analysis

Top Keywords

combined capillary
12
capillary electrophoresis
12
sensitive quantitative
8
myd88 gene
8
arms-pcr combined
8
detection
5
[arms-pcr combined
4
capillary
4
electrophoresis sensitive
4
quantitative method
4

Similar Publications